3 / 12 page
CY62138CV25/30/33 MoBL®
CY62138CV MoBL®
Document #: 38-05200 Rev. *D
Page 3 of 12
Electrical Characteristics Over the Operating Range
Parameter
Description
Test Conditions
CY62138CV25-55
CY62138CV25-70
Unit
Min.
Typ.[5]
Max.
Min.
Typ.[5]
Max.
VOH
Output HIGH Voltage
IOH = –0.1 mA
VCC = 2.2V
2.0
2.0
V
VOL
Output LOW Voltage
IOL = 0.1 mA
VCC = 2.2V
0.4
0.4
V
VIH
Input HIGH Voltage
1.8
VCC +
0.3V
1.8
VCC +
0.3V
V
VIL
Input LOW Voltage
–0.3
0.6
–0.3
0.6
V
IIX
Input Leakage Current GND < VI < VCC
–1
+1
–1
+1
µA
IOZ
Output Leakage
Current
GND < VO < VCC, Output Disabled
–1
+1
–1
+1
µA
ICC
VCC Operating Supply
Current
f = fMAX = 1/tRC
VCC = 2.7V
IOUT = 0 mA
CMOS Levels
7
15
5.5
12
mA
f = 1 MHz
1.5
3
1.5
3
ISB1
Automatic CE
Power-down Current
— CMOS Inputs
CE1 > VCC – 0.2V or CE2 < 0.2V
VIN > VCC – 0.2V or VIN < 0.2V, f =
fmax (Address and Data Only), f = 0
(OE, WE)
2
10
2
10
µA
ISB2
Automatic CE
Power-down Current
— CMOS Inputs
CE1 > VCC – 0.2V or CE2 < 0.2V
VIN> VCC − 0.2VorVIN <0.2V,f=0,VCC
= 2.7V
Parameter
Description
Test Conditions
CY62138CV30-55
CY62138CV30-70
Unit
Min.
Typ.[5]
Max.
Min.
Typ.[5]
Max.
VOH
Output HIGH Voltage
IOH = –1.0 mA
VCC = 2.7V
2.4
2.4
V
VOL
Output LOW Voltage
IOL = 2.1 mA
VCC = 2.7V
0.4
0.4
V
VIH
Input HIGH Voltage
2.2
VCC +
0.3V
2.2
VCC +
0.3V
V
VIL
Input LOW Voltage
–0.3
0.8
–0.3
0.8
V
IIX
Input Leakage Current GND < VI < VCC
–1
+1
–1
+1
µA
IOZ
Output Leakage
Current
GND < VO < VCC, Output Disabled
–1
+1
–1
+1
µA
ICC
VCC Operating Supply
Current
f = fMAX = 1/tRC
VCC = 3.3V
IOUT = 0 mA
CMOS Levels
7
15
5.5
12
mA
f = 1 MHz
1.5
3
1.5
3
ISB1
Automatic CE
Power-down Current
— CMOS Inputs
CE1 > VCC – 0.2V or CE2 < 0.2V
VIN > VCC – 0.2V or VIN < 0.2V, f =
fmax (Address and Data Only), f = 0
(OE, WE)
2
10
2
10
µA
ISB2
Automatic CE
Power-down Current
— CMOS Inputs
CE1 > VCC – 0.2V or CE2 < 0.2V, VIN
> VCC − 0.2V or VIN < 0.2V, f = 0,
VCC=3.3V