5 / 28 page
Page 5 / 28
SPECIFICATION
Liquid Crystal Display LC104S1-A1
2. Absolute Maximum Ratings
The following are maximum values which, if exceeded, may cause operation or damage to the unit.
Table 1. ABSOLUTE MAXIMUM RATINGS
Parameter
symbol
Values
Min.
Max.
Units
Notes
Power Input Voltage
Operating Temperature
Storage Temperature
Operating Ambient Humidity
Storage Humidity
V
CC
T
OP
T
ST
H
OP
H
ST
-0.3
0
-20
10
10
4.0
50
60
90
90
Vdc
°C
°C
%RH
%RH
At 25 +/- 5
°C
1
1
1
1
Note : 1. Temperature and relative humidity range are shown in the figure below.
Wet bulb temperature should be 39
°C Max, and no condensation of water.
90%
10
20
30
40
50
60
70
80
0
-20
0
10
20
30
40
50
Dry Bulb Temperature [C]
Wet Bulb
Temperature [C]
Storage
Operation
10%
40%
60%
60
Alpha Point Ltd.
Vernissakatu 8A
01300 Vantaa, Finland
Tel.: +358-9-34 64 34 1
Fax: +358-9-34 64 34 2
http://www.alpha.fi