9 / 12 page
CY62146CV30 MoBL™
Document #: 38-05203 Rev. **
Page 9 of 12
Typical DC and AC Parameters
Truth Table
CE
WE
OE
BHE
BLE
Inputs/Outputs
Mode
Power
H
X
X
X
X
High Z
Deselect/Power-Down
Standby (ISB)
L
X
X
H
H
High Z
Output Disabled
Active (ICC)
L
H
L
L
L
Data Out (I/OO – I/O15)
Read
Active (ICC)
L
H
L
H
L
Data Out (I/OO – I/O7);
I/O8 – I/O15 in High Z
Read
Active (ICC)
L
H
L
L
H
Data Out (I/O8 – I/O15);
I/O0 – I/O7 in High Z
Read
Active (ICC)
L
H
H
L
L
High Z
Output Disabled
Active (ICC)
L
H
H
H
L
High Z
Output Disabled
Active (ICC)
L
H
H
L
H
High Z
Output Disabled
Active (ICC)
L
L
X
L
L
Data In (I/OO – I/O15)
Write
Active (ICC)
L
L
X
H
L
Data In (I/OO – I/O7);
I/O8 – I/O15 in High Z
Write
Active (ICC)
L
L
X
L
H
Data In (I/O8 – I/O15);
I/O0 – I/O7 in High Z
Write
Active (ICC)
(Typical values are included for reference only and are not guaranteed or tested.
12.0
10.0
6.0
4.0
2.0
2.7
3.3
0.0
8.0
SUPPLY VOLTAGE (V)
MoBL2
(f = fmax, 55 ns)
(f = 1 MHz)
(f = fmax, 70 ns)
14.0
3.0
12.0
10.0
6.0
4.0
3.0
0
8.0
Standby Current vs. Supply Voltage
SUPPLY VOLTAGE (V)
MoBL2
2.0
2.7
3.3
50
30
20
10
SUPPLY VOLTAGE (V)
Access Time vs. Supply Voltage
0
40
60
3.0
2.7
3.3
Operating Current vs. Supply Voltage
MoBL2
Typical values are measured at VCC = VCC(typ.), TA = 25°C.)