Electronic Components Datasheet Search |
|
MKW2621 Datasheet(PDF) 2 Page - Total Power International |
|
MKW2621 Datasheet(HTML) 2 Page - Total Power International |
2 / 8 page 86 363 {50 {500 {15 MKW2637 85 363 {62.5 {625 {12 MKW2636 85 363 125 1250 12 MKW2633 82 382 295 2950 5.1 MKW2632 78 15 264 300 3000 3.3 48 ( 18 ~ 75 ) MKW2631 86 726 {50 {500 {15 MKW2627 85 726 {62.5 {625 {12 MKW2626 85 726 125 1250 12 MKW2623 82 764 295 2950 5.1 MKW2622 78 25 528 300 3000 3.3 24 ( 9 ~ 36 ) MKW2621 % (Typ.) mA (Typ.) mA (Typ.) mA mA VDC VDC @Max. Load @No Load @Max. Load Min. Max. Efficiency Input Current Output Current Output Voltage Input Voltage Model Number Model Selection Guide Six-Side Shielded Metal Case RFI Free-Air Convection Cooling % 95 --- Humidity ] +125 -50 Storage Temperature ] +100 -40 Case Operating Temperature ] +60 -40 Ambient Operating Temperature Unit Max. Min. Conditions Parameter Environmental Specifications Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings. mW 5,000 --- Internal Power Dissipation ] 260 --- Lead Temperature (1.5mm from case for 10 Sec.) VDC 100 -0.7 48VDC Input Models VDC 50 -0.7 24VDC Input Models Input Surge Voltage ( 1000 mS ) Unit Max. Min. Parameter Note : 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation at no-load will not damage these units. However, they may not meet all specifications. 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8.To order the converter with Remote on/off function ,please add suffix - RC ( EX : MK2621-RC ). 9. An optional internal filter is available. When the filter is added, the MKW2500 will meet EN55022-A. Add the suffix “ A” to the model number, e.g. MKW2621A. 10. Specifications subject to change without notice. Absolute Maximum Ratings MKW2600 / MKW2600A Series 2 MINMAX 2004/REV:3 |
Similar Part No. - MKW2621 |
|
Similar Description - MKW2621 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |