Electronic Components Datasheet Search |
|
PBA100F-24 Datasheet(PDF) 1 Page - Total Power International |
|
PBA100F-24 Datasheet(HTML) 1 Page - Total Power International |
|
1 / 1 page Unit type PBA100F Ordering information PBA 100 F -5 -O 1 2 3 4 5 R 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional C :with Coating G :Low leakage current (0.15mA max / ACIN 240V) E :Low leakage current and EMI class A (0.5mA max / ACIN 240V) T :Vertical terminal block J :Connector type (Only -24, -36, -48) R :with Remote ON/OFF N :with Cover (Only 24V UL508 pending) N1 :with DIN rail V :Output voltage setting potentiometer external- ly Specification is changed at option. Please consult us details. MODEL PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48 MAX OUTPUT WATTAGE[W] 66 100 94.5 102 105 108 100.8 100.8 DC OUTPUT 3.3V 20A 5V 20A 9V 10.5A 12V 8.5A 15V 7A 24V 4.5A 36V 2.8A 48V 2.1A SPECIFICATIONS MODEL PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48 VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC70 or DC100 optionally available *4) CURRENT[A] ACIN 100V 0.9typ 1.3typ ACIN 200V 0.5typ 0.7typ FREQUENCY[Hz] 50/60 (47 - 63) ACIN 100V 77typ 81typ 80typ 81typ 83typ 84typ 84typ 84typ INPUT EFFICIENCY[%] ACIN 200V 79typ 84typ 82typ 83typ 86typ 86typ 86typ 86typ POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typ ACIN 200V 0.87typ 0.93typ ACIN 100V 20typ (Io=100%) (At cold start) INRUSH CURRENT[A] ACIN 200V 40typ (Io=100%) (At cold start) OUTPUT LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1) VOLTAGE[V] 3.3 5 9 12 15 24 36 48 CURRENT[A] 20 20 10.5 8.5 7 4.5 2.8 2.1 LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max RIPPLE[mVp-p] 0to +50C*1 80max 80max 120max 120max 120max 120max 150max 150max -10 - 0C*1 140max 140max 160max 160max 160max 160max 200max 200max 0to +50C*1 120max 120max 150max 150max 150max 150max 250max 250max RIPPLE NOISE[mVp-p] -10 - 0C*1 160max 160max 180max 180max 180max 180max 300max 300max 0to+50C 50max 50max 90max 120max 150max 240max 360max 480max TEMPERATURE REGULATION[mV] -10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192max START-UP TIME[ms] 350typ(ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.60 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.0 39.0 - 53.0 OUTPUT VOLTAGE SETTING[V] 3.20 - 3.40 4.90 - 5.20 8.70 - 9.30 11.5 - 12.5 14.5 - 15.5 23.5 - 24.5 35.5 - 36.5 47.0 - 49.0 OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically PROTECTION OVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0 CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS ISOLATION REMOTE SENSING Optional (Only -3R3, -5 Option -K) REMOTE ON/OFF Optional (Required external power source) INPUT-OUTPUT -RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max ENVIRONMENT STORAGE TEMP. ,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max VIBRATION 19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input) SAFETY AND CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B NOISE REGULATIONS CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 OTHERS CASE SIZE/WEIGHT 32X93X147mm (without terminal block) (WXHXD) / 440g max (without cover) COOLING METHOD Convection *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and FG. * Parallel operation with other model is not possible. PBA-6 * Derating is required when operated with cover. * A sound may occur from power supply at peak loading. *4 Derating is required.Consult us for details. |
Similar Part No. - PBA100F-24 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |