Electronic Components Datasheet Search |
|
UCC3918N Datasheet(PDF) 6 Page - Texas Instruments |
|
UCC3918N Datasheet(HTML) 6 Page - Texas Instruments |
6 / 11 page UCC3918 LOW ONRESISTANCE HOT SWAP POWER MANAGER SLUS384B – NOVEMBER 1999 – REVISED JUNE 2000 6 www.ti.com APPLICATION INFORMATION estimating maximum load capacitance For worst-case constant-current load of value just less than the trip limit; COUT(max) can be estimated from: C OUT(max) + I MAX * I LOAD 22 103 C T V OUT Where VOUT is the output voltage and IMAX is the maximum sourcing current. For a resistive load of value RLOAD, the value of COUT(max) can be estimated from: C OUT(max) + 22 103 C T R LOAD n 1 1 * VOUT I MAX R LOAD UDG–97071 Figure 2. Load Curent, Timing Capacitor Voltage and Output Voltage of the UCC3918 Under Fault (6) (7) |
Similar Part No. - UCC3918N |
|
Similar Description - UCC3918N |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |