Electronic Components Datasheet Search |
|
BQ27350PWR Datasheet(PDF) 9 Page - Texas Instruments |
|
|
BQ27350PWR Datasheet(HTML) 9 Page - Texas Instruments |
9 / 33 page www.ti.com bq27350 Single Cell Li-Ion Battery Manager With Impedance Track Fuel Gauge Technology SLUS754 – MARCH 2007 4.1.1.1 Control( ): 0x00/0x01 Issuing a Control( ) command requires a subsequent two-byte sub-command (little endian format: least-significant byte written to lowest address location). These additional bytes specify the particular control function desired. The Control( ) command allows the host to control specific features of the bq27350 during normal operation and additional features when the bq27350 is in different access modes, as described in Table 4-2. Table 4-2. Control( ) Subcommands CNTL SEALED CNTL FUNCTION DESCRIPTION DATA ACCESS CONTROL STATUS 0x0000 Yes Reports the status of DF Checksum, Hibernate, IT, etc. DEVICE TYPE 0x0001 Yes Reports the device type (eg: "bq27350") FW VERSION 0x0002 Yes Reports the firmware version on the device type HW VERSION 0x0003 Yes Reports the hardware version of the device type DFCHECKSUM 0x0004 No Enables a DF checksum to be generated and reports on a read RESET DATA 0x0005 No Returns reset data Reserved 0x0006 No Not to be used PREV_MACWRITE 0x0007 No Returns previous MAC command code Reports the chemical identifier of the ImpedanceTrack™ CHEMID 0x0008 Yes configuration BOARD OFFSET 0x0009 No Forces the device Board Offset to be measured and stored CC INT OFFSET 0x000b No Forces the device to measure and store the internal CC offset SET HIBERNATE 0x0011 Yes Forces DF:Pack Configuration [HIBERNATE] to 1 CLEAR HIBERNATE 0x0012 Yes Forces DF:Pack Configuration [HIBERNATE] to 0 SEALED 0x0020 No Places the bq27350 in SEALED access mode IT ENABLE 0x0021 No Enables the ImpedanceTrack™ algorithm IFCHECKSUM 0x0022 No Reports the instruction flash checksum CALMODE 0x0040 No Places the bq27350 in calibration mode RESET 0x0041 No Forces a full reset of the bq27350 CONTROL STATUS: 0x0000 Instructs the gas gauge to return status information to Control addresses 0x00/0x01. The status word should include the following information. Table 4-3. CONTROL STATUS Flags Flags( ) bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 High Byte – FAS SS CSV CCA BCA – – Low Byte – – – – LDMD RUP_DIS VOK QEN FAS = Full access sealed (Sealed = 1) SS = Sealed state (Sealed = 1) CSV = Indicates a valid DF checksum has been generated CCA = Coulomb counter calibration active BCA = Board calibration active LDMD = Indicates Z-track alg, using const. power mode RUP_DIS = Indicates Ra table updates disabled VOK = Indicates voltages are OK for QMAX update if set QEN = QMAX updates enabled if set DEVICE TYPE: 0x0001 Instructs the gas gauge to return the device type to addresses 0x00/0x01. FW_VERSION: 0x0002 Instructs the gas gauge to return the firmware version to addresses 0x00/0x01. Submit Documentation Feedback GENERAL DESCRIPTION 9 |
Similar Part No. - BQ27350PWR |
|
Similar Description - BQ27350PWR |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |