5. Absolute Maximum Ratings
Parameter
Value
Supply Voltage, VDD (overvoltage)
+ 20 V
Reverse Voltage Protection
− 10 V
Positive Output Voltage – Standard Version
(Analog or PWM)
+ 10 V
+ 14 V (200 s max − TA = + 25°C)
Positive Output Voltage – SPI Version
VDD + 0.3V
Positive Output Voltage (Switch Out)
+ 10 V
+ 14 V (200 s max − TA = + 25°C)
Output Current (IOUT)
± 30 mA
Reverse Output Voltage
− 0.3 V
Reverse Output Current
− 50 mA
Operating Ambient Temperature Range, TA
− 40°C … + 150°C
Storage Temperature Range, TS
− 40°C … + 150°C
Magnetic Flux Density
± 700 mT
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
6. Detailed Description
As described on the block diagram (Figure 1 and Figure 2), the magnetic flux density parallel to the IC
surface (i.e. B//) is sensed through the Tria⊗is™ sensor front-end. This front-end consists into two
orthogonal pairs (for each of the two directions parallel with the IC surface i.e. X and Y) of conventional
planar Hall plates (blue area on Figure 4) and an Integrated Magneto-Concentrator (IMC
® yellow disk on
Figure 4).
Hall Plates
Figure 4 - Tria
⊗is™ sensor front-end (4 Hall plates + IMC® disk)