SMI30 Series Intrinsically Safe Sensors
5
These new water-tight aper-
tures for SM30 Series sen-
sors may be used to size and
shape the effective beam or
to limit excess gain for avoid-
ing "burn-through" effects.
Apertures are sold as a kit,
which includes a thread-on
stainless steel housing, a flat
glass lens, two quad-ring
seals, and 3 round and 3 slot-
ted aperture disks.
The stainless steel aperture
housing functions equally
wellwithVALOX®andstain-
less steel sensor models. The
glass lens is useful for pro-
tecting the SM30's acrylic
lens against substances that
are hostile to acrylics, such
as concentrated acids and alkalis and industrial solvents.
Aperture sizes include the following.
Round: .06", .12", and .70" diameter
Slotted: .04", .10", and .20" wide
APG30S Aperture Kit for SM30 Series Sensors (27533)
Accessories: apertures, barriers, kits, and mounting brackets
Models
with
10 ms
response
time
Models
with
1 ms
response
time
Emitters
Receivers
(light operate)
Receivers
(dark operate)
SMI306EYQ
(35277)
SMI30AN6RYQ
(35279)
SMI30RN6RYQ
(35281)
Emitters
Receivers
(light operate)
Receivers
(dark operate)
_
_
_
SMI306EQ
(35268)
SMI30AN6RQ
(35271)
SMI30RN6RQ
(35274)
Repeatability: 1 ms
Repeatability: 360
µs
SMI306ECQ
(35270)
SMI30AN6RCQ
(35273)
SMI30RN6RCQ
(35276)
Repeatability: 2.3 ms
Repeatability: 210
µs
SMI306EYCQ
(35278)
SMI30AN6RYCQ
(35280)
SMI30RN6RYCQ
(35282)
SMI306EBQ
(35269)
SMI30AN6RBQ
(35272)
SMI30RN6RBQ
(35275)
Repeatability: 1.6 ms
Sensor Models
Frequency "A"
Frequency "B"
Frequency "C"
(standard)
(special order)
(special order)
SMI30 Series Intrinsically Safe Sensors and Part Numbers
Models: part numbers, frequencies, and response times
Intrinsic Safety Kits for use with Intrinsic Safe Sensors
Kit CI2BK-1 (36860) includes a CI3RC2 current amplifier, one RS-
11 socket, one DIN-rail mount, and one single-channel intrinsically
safe barrier.
Kit CI2BK-2 (36605) includes a CI3RC2 current amplifier, one RS-
11 socket, one DIN-rail mount, and one dual-channel intrinsically
safe barrier.
Barriers are available separately:
Single channel barrier (model CIB-1, p/n 27030)
Dual channel barrier (model CI2B-1, p/n 36865)
Excess Gain Curve
100
10
DISTANCE
1,000
10,000
1 FT
0.3 m
10 FT
3 m
100 FT
30 m
1000 FT
300 m
E
X
C
E
S
S
G
A
I
N
I
SMI30 series
opposed mode
intrinsically safe
sensors
100,000
0
10ms response
models