10 / 32 page ZM7300G Series Digital Power Manager Data Sheet REV. 3.3 NOV 26, 2007 www.power-one.com Page 10 of 32 Table 1. DPM Setup Registers Address Offset 1 Register Name Content Register Type User Access Write Protect Initial Value 0x00 GD1[3:0] Group Definition Register 1 Static R/W yes 0x00000000 0x04 GD2[3:0] Group Definition Register 2 Static R/W yes 0x00000000 0x08 GAC Group A Configuration Static R/W yes 0x00 0x09 GBC Group B Configuration Static R/W yes 0x00 0x0A GCC Group C Configuration Static R/W yes 0x00 0x0B GDC Group D Configuration Static R/W yes 0x00 0x0C FPC1 Fault Propagation Configuration 1 Static R/W yes 0x00 0x0D FPC2 Fault Propagation Configuration 2 Static R/W yes 0x00 0x0E EPC Error Propagation Configuration Static R/W yes 0x00 0x0F IC1 Interrupt Configuration 1 Static R/W yes 0x00 0x10 IC2 Interrupt Configuration 2 Static R/W yes 0x00 0x11 IBL[1:0] IBV Low threshold Static R/W yes 0x00 0x13 IBH[1:0] IBV high threshold Static R/W yes 0xFF 0x15 ID[1:0] DPM Customer Identification Static OTP N/A 0xFFFF 0x17 PB1[3:0] Parallel Bus Register 1 Static R/W yes 0x00000000 0x1B PB2[3:0] Parallel Bus Register 2 Static R/W yes 0x00000000 0x1F PB3[3:0] Parallel Bus Register 3 Static R/W yes 0x00000000 0x23 PB4[3:0] Parallel Bus Register 4 Static R/W yes 0x00000000 0x27 PMC Power Manager Configuration Static R/W yes 0x00 0x28 PID[31:0] POL Identification Register Static R/W yes 0x00 0x80 RTC[3:0] Run Time Counter Run time R Read only value at last shut-down 0x84 PPS[3:0] POL Programming Status Run time R (4x) 0x00 0x88 EST Event Status Run time R 0x00 0x89 IBV[1:0] IB Voltage Run time R 0x00 0x8B STA Status of Group A Run time R 0x00 0x8C STB Status of Group B Run time R 0x00 0x8D STC Status of Group C Run time R 0x00 0x8E STD Status of Group D Run time R 0x00 0x8F REL[1:0] DPM Software Release Static R According to DPM type 0x91 PSS[3:0] POL Status Summary Run time R 0x00 0x95 DPMS DPM Status Run time R 0x01 0x96 WP Write Protection Volatile R/W 0x00 ______________________________________ 1 Writing into memory locations beyond address offset 0x96 must be avoided The static registers are saved in the non-volatile memory and used to store the system configuration data. The run-time registers contain status information and are evaluated during run-time. The Write Protection register WP is a volatile register that defaults to write protect at power-up. 10.1.3 POL Setup Registers Since the POL converters contain only RAM, the data defining performance parameters for each POL and Auxiliary Device, such as the output voltage, protection thresholds, feedback loop compensation, turn-on and turn- off delays, fault management settings, etc., is stored in the POL setup registers in the DPM. The POL setup registers consist of 23 data bytes and 2 CRC bytes. The Auxiliary Device setup registers occupy the same amount of bytes as a POL converter, but only 3 registers have meaningful data. The other registers should be filled with 0x00. The POL setup registers are listed in Table 2. |
Similar Part No. - ZM7304G-65505Y-B2 |
|
Similar Description - ZM7304G-65505Y-B2 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |