1P520 Datasheet(PDF) 3 Page - Anaren Microwave

Part # 1P520
Description  Pico Xinger 20dB Directional Coupler
Download  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  ANAREN [Anaren Microwave]
Direct Link  http://www.anaren.com
Logo ANAREN - Anaren Microwave

1P520 Datasheet(HTML) 3 Page - Anaren Microwave

  1P520 Datasheet HTML 1Page - Anaren Microwave 1P520 Datasheet HTML 2Page - Anaren Microwave 1P520 Datasheet HTML 3Page - Anaren Microwave 1P520 Datasheet HTML 4Page - Anaren Microwave  
Zoom Inzoom in Zoom Outzoom out
 3 / 4 page
background image
Available on Tape
and Reel For Pick and
Place Manufacturing.
USA/Canada:
Toll Free:
Europe
:
(315) 432-8909
(800) 544-2414
+44 2392-232392
Model 1P520
Rev B
VSWR & DIRECTIVITY (CONTINUED)
internal meandering of the coupled lines and
limitations of building perfect 50
Ω transitions at the
input and output ports of the device are the most
significant
factors
against
perfect
VSWR
and
directivity. Typically, VSWR and directivity of 1.15:1
and 25 dB respectively are achieved in practice.
INSERTION LOSS
Coupler insertion loss is defined as the log of the
input power divided by the sum of the power at the
two output ports.
In practice, typical loss is
approximately 0.20 dB.
Specification limits are
somewhat higher due to imperfect test conditions;
surface mount couplers must be tested in test
fixtures that negatively affect results.
PIN CONFIGURATION
The 1P520’s have an orientation marker to denote
either pin 1 or pin 2.
When the input port is
identified, the output, coupled and isolated ports are
known automatically. For example, if the input port
for a device was selected to be Pin 1, Pin 2
automatically becomes the output port, Pin 4
becomes the coupled port, and Pin 3 is the isolated
port. Similarly, if Pin 2 was to be selected as the
input port, the adjacent port on the long side (Pin 1)
is the output port, the adjacent port on the short side
(Pin 3) is the coupled port, and the opposite port
(Pin 4) is the isolated port. Either port on the same
side as the orientation marker can be selected as
the input port, as shown in the table, which shows
both pin configurations
. The use of pin 1 or pin 2 as
the input port ensures phase consistency as well as
maximum power handling.
MOUNTING
For
Xinger
surface
mount
couplers
to
operate
optimally, there must be 50
Ω transmission lines
leading to and from all of the RF ports.
To ensure
proper electrical and thermal performance, there must
be a ground plane with 100% solder connection
underneath the part. If either of these two conditions is
not satisfied, insertion loss, coupling, VSWR and
directivity may not meet published specifications.
SUGGESTED FOOTPRINT
1P520* Mounting Footprint
Dimensions are in Inches [Millimeters]
To ensure proper electrical and thermal performance
there must be a ground plane with 100%
solder connection underneath the part
4X .063 SQ
[1.60]
4X .034
[0.86]
.170
[4.32]
.120
[3.05]
4X 50
Transmission
Line
Multiple
plated thru holes
to ground


Similar Part No. - 1P520

ManufacturerPart #DatasheetDescription
logo
Anaren Microwave
1P520S ANAREN-1P520S Datasheet
503Kb / 4P
   Pico Xinger 20dB Directional Coupler
1P520S ANAREN-1P520S Datasheet
505Kb / 5P
   Pico Xinger 20dB Directional Coupler
1P520S ANAREN-1P520S_14 Datasheet
505Kb / 5P
   Pico Xinger 20dB Directional Coupler
More results

Similar Description - 1P520

ManufacturerPart #DatasheetDescription
logo
Anaren Microwave
JP520S ANAREN-JP520S_14 Datasheet
504Kb / 5P
   Pico Xinger 20dB Directional Coupler
1P520S ANAREN-1P520S_14 Datasheet
505Kb / 5P
   Pico Xinger 20dB Directional Coupler
1P620 ANAREN-1P620_10 Datasheet
333Kb / 10P
   Pico Xinger 20dB Directional Coupler
1P520S ANAREN-1P520S Datasheet
503Kb / 4P
   Pico Xinger 20dB Directional Coupler
1P620 ANAREN-1P620 Datasheet
163Kb / 4P
   Pico Xinger 20dB Directional Coupler
1P620S ANAREN-1P620S Datasheet
514Kb / 4P
   Pico Xinger 20dB Directional Coupler
JP520S ANAREN-JP520S Datasheet
502Kb / 4P
   Pico Xinger 20dB Directional Coupler
1P610 ANAREN-1P610 Datasheet
161Kb / 4P
   Pico Xinger 10dB Directional Coupler
1P510 ANAREN-1P510 Datasheet
400Kb / 4P
   PICO XINGER 10dB DIRECTIONAL COUPLER
1P610S ANAREN-1P610S Datasheet
513Kb / 4P
   Pico Xinger 10dB Directional Coupler
More results


Html Pages

1 2 3 4


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.NET
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com