Electronic Components Datasheet Search |
|
3RHP1240D5 Datasheet(PDF) 1 Page - Crydom Inc., |
|
3RHP1240D5 Datasheet(HTML) 1 Page - Crydom Inc., |
1 / 6 page 3RHP Series DC Control • 40 and 50A output • Voltage ratings to 240 VAC • Lifetime 2 million operations at full load • LED input status indicator • Wire, lug or quick connect termination • Industry Standard DP contactor mounting PRODUCT SELECTION Control Voltage 40A 120 VAC 50A 120 VAC 40A 240 VAC 50A 240 VAC 4.5-5.5 VDC 3RHP1240D5 3RHP1250D5 3RHP2440D5 3RHP2450D5 10-15 VDC 3RHP1240D12 3RHP1250D12 3RHP2440D12 3RHP2450D12 22-27 VDC 3RHP1240D24 3RHP1250D24 3RHP2440D24 3RHP2450D24 OUTPUT SPECIFICATIONS (voltage) Description 120 VAC 240 VAC Operating Voltage (47-63Hz) [Vrms] 100-120 208-240 Maximum Off-State Leakage Current per channel 0.05 mA @ 120 VAC 0.06 mA @ 240 VAC OUTPUT SPECIFICATIONS (current) Description 40A 50A Maximum Load Current per phase @ 40°C [Arms] (1) 40A Resistive / 30A Inductive 50A Resistive / 40A Inductive Power terminals 1/4" Quick Connect and 10x32 binder head screws 1/4" Quick Connect and box lugs Wire Size 8-14 AWG 6-14 AWG INPUT SPECIFICATIONS Description SUFIX D5 SUFIX D12 SUFIX D24 Coil Voltage 4.5-5.5 VDC 10-15 VDC 22-27 VDC Max. Reverse Voltage -5.5 VDC -15.5 VDC -27.5 VDC Input Current 12mA @ 5 VDC 12mA @ 12 VDC 12mA @ 24 VDC Min. Turn-On Voltage 4.5 VDC 9.5 VDC 9.5 VDC Min. Turn-Off Voltage 1 VDC 2 VDC 2 VDC GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input to Output 4000 Vrms Dielectric Strength, Input/Output to ground 2500 Vrms Contacts (2) Three Normally Open Ambient Operating Temperature Range (3) -20 to 75 °C Ambient Storage Temperature Range -40 to 100 °C Max. Turn-On Time 50/60 Hz 20 ms / 16.6 ms Max. Turn-Off Time 50/60Hz 40 ms / 32 ms Maximum Number of Operations 30 per Minute Lifetime Number of Operations @ Rated Current (4) > 2 Million Weight (typical) 1.19 lbs (540 g) Screw Torque (input/Output) 40A 5.31 in lb (0.6 Nm) / 18 in lb (2.1 Nm) Screw Torque (input/Output) 50A 5.31 in lb (0.6 Nm) / 25 in lb (2.9 Nm) GENERAL NOTES (1) See Derating curves for additional operating conditions. (2) The R HP includes a Solid State Relay, therefore electrical isolation is not provided. (3) The R HP includes over temperature protection for the solid state relay. (4) 40°C ambient temperature, 30 operations/min, maximum voltage control. |
Similar Part No. - 3RHP1240D5 |
|
Similar Description - 3RHP1240D5 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |