|
| B116LP |
|
||
|
SYSTEMSENSOR |
|
1 page
D150-01-00 1 I56-599-03R B116LP Plug-in Detector Base For use with the following smoke detectors: In US: 1151, 2151 In Canada: 1151A, 2151A In Europe: 1151E, 2151E INSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 Before Installing Please thoroughly read the System Sensor manual I56-407, Guide for Proper Use of System Smoke Detectors, which pro- vides detailed information on detector spacing, placement, zoning, wiring, and special applications. Copies of this manual are available at no charge from System Sensor. (For installation in Canada, please refer to CAN4-S524, Standard for the Installation of Fire Alarm Systems and CEC Part 1, Sec. 32.) NOTICE: This manual should be left with the owner/user of this equipment. IMPORTANT: The detector used with this base must be Specifications Base Diameter: 6.2 inches (157 mm) Base Height: 0.95 inches (24 mm) Weight: 0.3 lb. (130 g) Mounting: 4-inch square box with or without plaster ring. Min. Depth–1.5 inches 4-inch octagon box. Min. Depth–1.5 inches 3-1/2 inch-octagon box. Min. Depth–1.5 inches 50 mm box 60 mm box 70 mm box Operating Temperature Range: 0° to +49°C (32° to 120°F) US and Canadian Installations 10°to 60°C (14° to 140°F) European Installations Operating Humidity Range: 10% to 93% Relative Humidity Electrical Ratings – includes base and detector System Voltage: 24 VDC Maximum Ripple Voltage: 4 Volts peak to peak Start-up Capacitance: 0.02µF Maximum Standby Ratings: 15 VDC Minimum 35 VDC Maximum 120 µA Maximum Alarm Ratings: 8 V Minimum at 16 mA 12 V Maximum at 100 mA (Alarm current MUST be limited to 100 mA maximum by the control panel.) Relay Contact Ratings: Resistive or Inductive (60% power factor) Load Form C:* 2.0A @ 30 VAC/DC 0.6A @ 110 VDC 1.0A @ 125 VAC Reset Voltage: 1.4 VDC Minimum Reset Time: 0.3 Seconds Maximum Start-up Time: 34.0 Seconds Maximum *For Canadian installations relay contact ratings are 2.0A @ 30 VAC/DC. tested and maintained regularly following NFPA 72 require- ments. The detector used with this base should be cleaned at least once a year. General Description The model B116LP plug-in detector base is used with System Sensor model 1151, 1151A, and 1151E ionization detector heads and model 2151, 2151A, and 2151E photo- electronic detector heads. The capability of plugging these detectors into a variety of special bases makes them more versatile than equivalent direct-wired models. Refer to the System Sensor catalog for other available plug-in detector bases. |
|
Related Electronics Part Number |
| Part Number | Components Description | Html View | Manufacturer |
| B406B | Plug-in Detector Base | 1 2 3 4 | Systemsensor advanced ideas. |
| B110LP | Plug-in Detector Base | 1 2 3 4 | Systemsensor advanced ideas. |
| B110RLP | Plug-in Detector Base | 1 2 3 4 | Systemsensor advanced ideas. |
| B112LP | Plug-in Detector Base | 1 2 3 4 | Systemsensor advanced ideas. |
| B114LP | Plug-in Detector Base | 1 2 | Systemsensor advanced ideas. |
| 7251 | Low-Profile Plug-in Intelligent Laser Smoke Detector | 1 2 | Systemsensor advanced ideas. |
| 1451A | Plug-in Smoke Detector | 1 2 3 4 | Systemsensor advanced ideas. |
| 4451HT | Plug-in 190°F Thermal Detector | 1 2 | Systemsensor advanced ideas. |
| IL205AT_05 | Optocoupler Phototransistor Output With Base Connection in SOIC-8 package | 1 2 3 4 5 More | Vishay Siliconix |
| TPR175 | high power COMMON BASE bipolar transistor. | 1 2 3 | GHz Technology |
Link URL |
Sponsor of Alldatasheet |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Bookmark | Link Exchange | Manufacturer List All Rights Reserved© Alldatasheet.com 2003 - 2012 |
| Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com | Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl |