Electronic Components Datasheet Search |
|
CAB600-8 Datasheet(PDF) 2 Page - Gamewell-FCI by Honeywell |
|
CAB600-8 Datasheet(HTML) 2 Page - Gamewell-FCI by Honeywell |
2 / 4 page GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 CS-2005 Rev. A page 2 of 4 www.gamewell-fci.com The Reset key returns the control panel to idle mode after an alarm condition has been cleared. Trouble conditions that have been cleared will automatically return the control panel to idle mode if the problem has been corrected. Trou- ble conditions that have been acknowledged will resound the internal sounder if the condition is not corrected within a programmed time period. The Signal Silence key deactivates notification appliances. This function can be modified by user programming to operate only after a specified time period. There are three additional programmable switches avail- able to control application-specific operations. Keys for programming and bypass functions, along with LEDs for active and trouble conditions, are provided for the City Connection, and two signal circuits which are part of the Common Control section. Other Panel/System Components The IF650 COMMON CONTROL SECTION comprises the heart of the system. The common control section houses the main CPU and all system memory as well as providing local and remote communications and supervision. The common control contains the common system relays, two signal circuits, city tie, and optional EIA-232 port. All inter- action with the common control section is through the oper- ator’s display panel. Four relay circuits control auxiliary functions. The relays, rated at 10 Amps, are controlled by the main CPU. Two 24 VDC notification appliance circuits (NAC) are provided. The NACs can provide a steady or coded output. All circuits are power-limited per NEC 760 and UL 864. The IF650 ANALOG INTERFACE MODULE (AAM95- 1,2,4) occupies one bay and has from one to four circuits that can monitor and control up to 126 addressable/analog devices each for a total of 504 points per bay. Gamewell- FCI IF650 systems can be configured for up to 2016 points. The analog interface module has a dedicated microproces- sor which simultaneously communicates with the con- nected field devices and the main CPU. This feature allows the IF650 to maintain maximum communications speed throughout the system. Analog/addressable circuits can be wired as non-polarized in Style 4, 6, or 7. The communica- tions protocol provides for alarm verification per detector, detector adjustability and compensation, adjustable analog heat detector range (131°F to 194°F/55°C to 90°C), circuit isolation, and priority interrupts. Priority interrupts allow contact-type devices such as manual fire alarm stations to interrupt the polling cycle and transmit their addresses at any time during a polling sequence. The digital protocol allows the IF650 to operate on most types of field wiring, greatly expanding its use in retrofit applications (consult Gamewell-FCI Technical Support for specific wiring requirements). The CONVENTIONAL INPUT MODULE (CIM-8) occupies one bay and provides eight hard-wired input circuits for monitoring conventional detectors and contact-type devices. The CIM-8 monitors and reports each circuit’s analog status to the CPU as it distinguishes between detectors and contact devices and determines if two or more detectors are in alarm. Each input module uses one slot in the MPU bus and is supplied with its own display module. The display module provides LED annunciation of alarm and trouble conditions and has a switch (per circuit) for programming and bypass functions. The display has space for user-defined custom labels for each circuit. Beyond normal alarm and supervisory functions, the input circuits can be programmed for Remote Acknowledge, Reset, Signal Silence, and Release Abort switches. Cir- cuits can be wired for Style B, D, and E service and are capable of monitoring normally-closed devices. The 600 Series UNIVERSAL SIGNAL MODULE (USM-8) occupies one bay and is a multifunctional eight-circuit out- put module. USM-8 modules communicate via the MPU bus and require one expansion slot each. The USM can be configured as 24 VDC signaling circuits. Modules are pro- grammed in two-circuit increments, making it possible to perform all four functions with a single module. Signal cir- cuits provide steady or coded outputs. All circuits are power-limited per NEC 760 and UL 864. Signal circuits can be wired in either Style Y or Z. Signal modules are supplied with their own display that provides LED annunciation of activation and trouble conditions and has a switch (per cir- cuit) for programming and bypass functions. The display has space for user-defined custom labels for each circuit. The 600 Series POWER SUPPLY (MPS-8) furnishes sys- tem operating and signaling power. The supply is equipped with a battery charger for maintaining the secondary power source. The power supply is monitored by the main CPU to ensure that adequate power levels are maintained. The power supply design allows for high efficiency while provid- ing precise power output. The battery charger is capable of operating with lead-acid batteries and maintaining up to 50 AH batteries. Multiple auxiliary power supplies (APS-8) may be added to the system when additional power is required. The 600 Series RELAY MODULE (RM-8) supplies eight NO/NC relays for control of auxiliary functions. The relays are controlled by the main CPU and are fully programma- ble. Each position on the MPU bus can accommodate a relay module. The relays are rated at 10 Amps and each is |
Similar Part No. - CAB600-8 |
|
Similar Description - CAB600-8 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |