Electronic Components Datasheet Search |
|
TMP150-15 Datasheet(PDF) 1 Page - Tumbler Technologies + TRUMPower |
|
TMP150-15 Datasheet(HTML) 1 Page - Tumbler Technologies + TRUMPower |
1 / 2 page DESCRI PTI O N The TMP150 is a series of medical grade, class I and class II, AC/DC desktop power adapters of 132 to 150 watts output power. They are enclosed in a 94V-1 rated case with an IEC 320/C14 or IEC 320/C18 AC inlet to mate with interchangeable cord for world-wide use. All models meet CISPR 11 and FCC class B emission limits, and are designed for medical applications. FEAT URES ‧ Low safety ground leakage current ‧ Optional output connectors ‧ 100% burn-in ‧ 90 to 264VAC w i de input range ‧ Ov erv o ltage & ov ercurrent protections ‧ 0.98 PFC ‧ Compliant w i th CEC and Energy S tar efficiency lev e l IV requirement s ‧ No load consumption less than 0.5W ‧ Av erage activ e efficiency ≧ 85% ‧ Compliant w i th RoHS requirements INPUT SPECIFICAT IONS Input v o lt age : Input frequency : Input current : Earth leakage current : (Class I) Enclosure leakage current: (Class II) OUTPUT SPECIFICATIONS Output voltage/current: See rating chart Total output power: See rating chart Ripple and noise: 2% peak to peak maximum Overvoltage protection: Set at 112 – 140% of its nominal output voltage Overcurrent protection: All outputs protected to short circuit conditions Temperature coefficient: All outputs ±0.04%/ºC maximum Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500µs after a 25% step load change ENVIRONMENTA L SPECIFICAT IONS Operating temperature : S t orage temperature : Relativ e humidity : Derating: 0ºC to +60ºC -40ºC to +85ºC 5% to 95% non-condensing Derate from 100% at +40ºC linearly to 50% at +60ºC Safety Standard Approvals : GENERAL SPECIFICATIONS Switching frequency: 30KHz ~ 110KHz Power factor: 0.98 typical at 115VAC Efficiency: 85% min. Hold-up time: 15 msec minimum at 110VAC Line regulation: ±0.5% maximum at full load Inrush current: 60 amps @ 115VAC or 100 amps @ 230VAC, at 25ºC cold start Withstand voltage: 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF: 150,000 hours minimum at full load At 25ºC ambient, calculated per MIL-HDBK-217F EMC Performance EN55011: Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated VCCI: Class B conducted, Class B radiated EN61000-3-2: Harmonic distortion, Class D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8KV air and ±6KV contact EN61000-4-3: Radiated immunity, 3V/m EN61000-4-4: Fast transient/burst, ±2KV EN61000-4-5: Surge, ±1KV diff, ±2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: Magnetic field immunity, 3A/m EN61000-4-11 : Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms (LVD) TMP150 SERIES Class I, Class II 150 WATT MEDICAL POWER ADAPTERS RoHS UL 60601-1 CSA C22.2 No. 601.1 TÜV EN60601-1 TRUMPower Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com 90 to 264VAC 47 to 63Hz 2.0A (rms) for 115VAC 1.0A (rms) for 230VAC 90µA max. @ 115VAC, 60Hz 150µA max. @ 230VAC, 50Hz 90µA max. @ 264VAC, 50Hz |
Similar Part No. - TMP150-15 |
|
Similar Description - TMP150-15 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |