Electronic Components Datasheet Search |
|
PSE100B15 Datasheet(PDF) 1 Page - Powerbox |
|
PSE100B15 Datasheet(HTML) 1 Page - Powerbox |
1 / 2 page 411 Your dependable power partner – www.powerbox.com.au PSE100 Series 60-100 W A TTS DC/DC SINGLE OUTPUT Features • Under voltage logic alarm. • Conformally coating, tropic. • Reverse input voltage protection. • High efficiency. • Fully encapsulated, meets IP30 standard. • Convectional cooled. Specifications INPUT Voltage See table Isolation Input – Output: 2kVdc (Input code A, B) Input – Output: 2.5kVac / 4kVdc (Input code C/ D) Input – Case: 2kVdc (Input code A, B) Input – Case: 2.5kVac / 4kVdc (Input – code C/ D) Output – Case: 2kVdc Reverse voltage protection Yes. OUTPUT Voltage See table. Current See table. Source regulation 0.2%. Load regulation 0.2% (0-100% load) Output ripple (100kHz) 10mV p-p (typical) Voltage adjustment 90% - 110%. Current limit protection 105%. Under voltage logic alarm 90% of nominal output. Soft start Yes. Start-up time 1s. Hold-up time 2-10ms Efficiency 80-88% ENVIRONMENTAL Operating temperature -25°C to +70°C (100% load, O/P > 10V). -25°C to +55°C (100% load, O/P < 10V). Temperature coefficient 0.02% / °C. Storage temperature -40°C to 85°C. Conformal coating Conformal coated to withstand non-condensing tropical environment RH 95% MECHANICAL Mechanical dimensions 3U x 8TE x 167mm Weight 0.85kg GENERAL Cooling Convectional cooling. Optional features -Overvoltage protection, option A. The output voltage is limited to 15% nominal output voltage. A thyristor short- circuit the output. -Undervoltage alarm with relay, option B. The logic alarm output is replaced with Relay with selectable alarm logic NO or NC. -Built in series diode, option C. A series diode on the output, when output is connected in parallel with other power supplies to achieve redundancy. Output power might be derated. -Remote sense, option S. The voltage sensing can be put at the load to compensate for voltage drop. This is standard feature on 5V output. -Inrush current limit with NTC, option H. Only for C -input code. Reduce the inrush current during the start up. The input voltage range will be affected. - 2.5kVac isolation input/case, option E1. On A and B inputs. The emission level increase to level A. - 2.5kVac isolation output/case, option E2. The emission level will increase to level A. -Train input, option T. Input voltage range according to train Standard EN50155 and IEC 60751. - Euro panel, option L 8TE for PSE 100, 10TE for 5V output with extra cooler. - Wall mounting panels, option N. Wall mounting panel with connector holder The female connector has to be chosen. - H15 screw type female, H15-S - H15 fast-on 6.3mm female, H15-T - Din rail TS35 clips, option Q. STANDARDS Safety IEC60950-1: 2001 EMI standards EN55011/EN55022 class B, IEC/EN61000-6-2, C-Tick AS/NZS CISPR11: 2002 Group1 Class A EMC standards EN61000-6-2, EN/IEC61000-4-4, EN61000-4-5 |
Similar Part No. - PSE100B15 |
|
Similar Description - PSE100B15 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |