Electronic Components Datasheet Search |
|
MAP55-4000 Datasheet(PDF) 2 Page - Power-One |
|
MAP55-4000 Datasheet(HTML) 2 Page - Power-One |
2 / 3 page 2 INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 90 132 VAC 175 264 Input Frequency AC input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC Hold-up Time Nominal AC Input Voltage (115VAC), full rated load. 20 ms Input Current 90 VAC (55W load). 1.6 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C. 38 APK Operating Frequency Switching frequency of power supply (varies with load). 22 180 kHz OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full load, 115VAC. Varies with distribution of loads among outputs. 73 % Minimum Loads MAP55-1012 0.21 MAP55-1024 0.11 Amps MAP40-1005 and all multiple output models, main channel only. 0.50 Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart. Output Power Continuous output power, all multiple output models. 55 Watts Peak output power (60s maximum, 10% duty cycle), all multiple output models. 65 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1, V2. 1 % Regulation Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264 VAC, See Model Selection Chart. changes in load starting at 20% load and changing to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% 500 µs load change, 4% max. deviation. (Main output of multiple output units). Turn-on Delay Time required for initial output voltage stabilization. 1 4 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90% (Note 1). 7 ms NOTES: 1) Nominal rise time for MAP55-1024 is 36 msec. INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection MAP40-1005 5.5 6.8 MAP55-1012 17.5 19.7 V MAP55-1024 32.0 36.0 Main output only of multiple output units. 5.6 6.8 Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 No. 234/950. Approved. EN60950 (TUV). Dielectric Withstand Input to output. 2600 VDC Voltage Electromagnetic FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated. B Interference, EN55022 / CISPR 22 conducted. B Class Conducted EN55022 / CISPR 22 radiated. A Insulation Resistance Input to output. 7 M Ω Leakage Current Per EN60950, 264VAC. 500 µA MAP55 SERIES |
Similar Part No. - MAP55-4000 |
|
Similar Description - MAP55-4000 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |