Electronic Components Datasheet Search |
|
E5ZN-2QNH03P-FLK Datasheet(PDF) 3 Page - Omron Electronics LLC |
|
E5ZN-2QNH03P-FLK Datasheet(HTML) 3 Page - Omron Electronics LLC |
3 / 13 page E5ZN 3 Specifications ■ Ratings Note: 1. Do not use an inverter output for the power supply. (Refer to Safety Precautions for All Temperature Controllers.) 2. OMRON G32A-EA Cycle Controller Unit (load impedance 352 Ω) can be used. ■ Input Range Platinum Resistance Thermometer Models and Thermocouple Models The applicable standards for the input types are as follows: • K, J, T, E, N, R, S, B: JIS C1602-1995, IEC584-1 • L: Fe-CuNi, DIN 43710-1985 • U: Cu-CuNi, DIN 43710-1985 • JPt100: JIS C 1604-1989, JIS C 1606-1989 • Pt100: JIS C 1604-1997 IEC 751 Shaded parts indicate the settings at the time of purchase. Power supply voltage 24 VDC Allowable voltage range 85% to 110% of the rated power supply voltage Power consumption Approx. 3 W Sensor input Thermocouple: K, J, T, E, L, U, N, R, S, B Infrared temperature sensor (ES1B series): 10 to 70 °C, 60 to 120°C, 115 to 165°C, 140 to 260°C Voltage input: 0 to 50 mV Platinum resistance thermometer: Pt100, JPt100 Control output Voltage output (for driving SSR) Output voltage: 12 VDC ±15% (PNP); Maximum load current: 21 mA; Equipped with short-circuit protection circuit Transistor output Maximum operational voltage: 30 VDC; Maximum load current: 100 mA; Residual voltage: 1.5 V max.; Leakage current: 0.4 mA max. Current output Current output range: 4 to 20/0 to 20 mA DC; Load: 350 Ω max. (See note 2.) Auxiliary output Transistor output Sourcing Maximum operating voltage: 30 VDC; Maximum load current: 50 mA; Residual voltage: 1.5 V max.; Leakage current: 0.4 mA max. Sinking Linear voltage output Voltage output range: 1 to 5/0 to 5 VDC; Load: 10 k Ω min. Event input Contact output ON: 1 k Ω max., OFF: 100 kΩ min. Discharge current: Approx. 7 mA Non-contact output ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. Discharge current: Approx. 7 mA Number of input and control points Input points: 2, Control points: 2 Setting method Via communications or using the Setting Display Unit (E5ZN-SDL) Control method 2-PID or ON/OFF control Other functions Heater burnout detection function, transfer output function Multi-SP and RUN/STOP switching using event input Ambient operating temperature −10 to 55°C (with no icing or condensation) For 3 years of assured use: −10 to 50°C Ambient operating humidity 25% to 85% Storage temperature −25 to 65°C (with no icing or condensation) 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 −100 −200 01234 0 1 2 3 4 17 5 6 7 18 8 9 10 11 12 13 14 15 16 −200 −200 −199.9 −199.9 500.0 500.0 0.0 0.0 100.0 100.0 −20.0 −100 −20.0 −200 −199.9 −199.9 0 −100 −200 −200 0 0 100.0 0 0 0 0 260 165 120 90 400 400 850 600 400.0 400.0 400.0 500.0 850 850 1300 1300 1700 1700 1800 Platinum resistance thermometer models Platinum resistance thermometer Input type Name Setting number KJ T E L U N R S B Pt100 JPt100 Thermocouple Thermocouple models Infrared temperature sensor Analog input 0 to 50 mV −1999 to 9999 or −199.9 to 999.9 by scaling 10 to 70 °C 60 to 120 °C 115 to 165 °C 160 to 260 °C |
Similar Part No. - E5ZN-2QNH03P-FLK |
|
Similar Description - E5ZN-2QNH03P-FLK |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |