Electronic Components Datasheet Search |
|
VB-5211 Datasheet(PDF) 2 Page - Omron Electronics LLC |
|
VB-5211 Datasheet(HTML) 2 Page - Omron Electronics LLC |
2 / 5 page VB 2 Specifications Approved Standards Ratings Standard Model Note: The above currents are steady-state currents. Micro Load Ratings Approved Standard Ratings TÜV (EN60947-5-1) (Grand terminal models only) Standard Model Micro Load Model CCC (GB14048.5) Characteristics Note: The above values are initial values. * The values are calculated at an operating temperature of 5°C to 35 °C, and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments. Engineering Data Electrical Durability (with more than 300,000 Operations) (Ambient temperature: 5 °C to 35°C; Ambient humidity: 40% to 70%) Agency Standards File No. Approved models TÜV Rheinland EN60947-5-1 (IEC947-5-1) J50062491 Only models with ground terminals CCC (CQC) GB14048.5 2003010305077628 Ask your OMRON representative for information on approved models. Rated voltage Resistive load NC NO 125 VAC 250 VAC 10 A 10 A 125 VDC 250 VDC 0.6 A 0.3 A Inrush current NC 24 A max. NO 24 A max. Rated voltage Resistive load 125 VAC 0.1 A 8 VDC 30 VDC Applicable category AC-15 DC-15 Rated operating current (Ie) 2 A 2 A Rated operating voltage (Ue) 250 V 48 V Applicable category AC-14 DC-15 Rated operating current (Ie) 0.1 A 0.1 A Rated operating voltage (Ue) 125 V 30 V Applicable category and ratings AC-15 2 A/250 VAC Degree of protection IP67 Durability * Mechanical 5,000,000 operations min. Electrical 300,000 operations min. (10 A at 250 VAC, resistive load) Operating speed 0.1 mm to 0.5 m/s Operating frequency Mechanical 120 operations min. Electrical 30 operations min. Rated frequency 50/60 Hz (AC) Insulation resistance 100 M Ω min. (at 500 VDC) Contact resistance 15 m Ω max. (initial value) Dielectric strength Between terminals of same polarity 1,000 VAC/Uimp 4,000 VAC Between current- carrying metal parts and ground 1,500 VAC/Uimp 4,000 VAC Between each terminal and non- current-carrying metal part 1,500 VAC/Uimp 4,000 VAC Between terminals of different polarity Uimp 4 kV (EN60947-5-1) Rated insulation voltage (Ui) 300 VAC (EN60947-5-1) Switching overvoltage 1,000 V max. (EN60947-5-1) Pollution degree (operating environment) 3 (EN60947-5-1) Short-circuit protective device (SCPD) 10 A fuse type gG or gI (IEC269) Conditional short-circuit current 100 A (EN60947-5-1) Conventional enclosed thermal current (Ithe) 5 A, 0.5 A (EN60947-5-1) Protection against electric shock Insulation class I (Use the grounding terminal or ground on the machine side.) Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Destruction 1,000 m/s2 min. Malfunction 200 m/s2 min. Ambient operating temperature –10 °C to 80°C (with no icing) Ambient operating humidity 35% to 95% Weight Approx. 580 g (in the case of VB-4211) 1,000 300 500 200 700 100 70 10 30 50 0 0.5 2 15 4 36 7 9 8 11 10 12 Switching current (A) Operating frequency: 30 operations/min 250 VAC, cos φ = 1 |
Similar Part No. - VB-5211 |
|
Similar Description - VB-5211 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |