Electronic Components Datasheet Search |
|
AMEOC40-24SMAZ Datasheet(PDF) 2 Page - AIMTEC |
|
AMEOC40-24SMAZ Datasheet(HTML) 2 Page - AIMTEC |
2 / 4 page Series AMEOC40-MAZ 40 Watt | AC/DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R7.F 2 of 4 North America only Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 3 sec 4000 VAC Isolation Resistance >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 47 KHz Over current protection Auto recovery 110 140 % Over voltage protection Zener diode clamp 110 % Short circuit protection Hiccup mode, indefinite Short Circuit restart Auto recovery Operating temperature With derating above 55ºC -40 - +85 oC Maximum case temperature 100 oC Storage temperature -40 to +95 oC Temperature coefficient 0.02 % / oC Cooling Free air convection Humidity Non condensing 95 % RH Weight 145 g Dimensions (L X H X W) 4.92 x 2.32 x 1.02 inches / 125 x 59 x 26mm MTBF > 800 000 hrs (MIL-HDBK -217F, t=+25 oC) Environment Approval Test Parameters Conditions Shock Wave form Half sine wave Acceleration amplitude 5gn Bump duration 30 ms Converter operation Before and after test, body mounted (on chassis) Number of bumps 18 (3 in each direction for every axis) Vibration Test mode Sweep sine, 10-100Hz, speed 0.05Hz/s Displacement 1 mm Acceleration 3g, 3 loops 30min one cycle, 3h total, every axis tested Converter operation Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals cULus, CE, CB Scheme Standards Medical Electrical Equipment IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90 Information technology Equipment EN 60950-1:2006+A11:2009 Harmonic Current Emissions IEC/EN 61000-3-2, (EN60555-2) EMI - Conducted and radiated emission EN55011, class B Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 RF, Electromagnetic Field Immunity IEC 61000-4-3 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Surge Immunity IEC 61000-4-5 RF, Conducted Disturbance Immunity IEC 61000-4-6 Power frequency Magnetic Field Immunity IEC 61000-4-8 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 |
Similar Part No. - AMEOC40-24SMAZ |
|
Similar Description - AMEOC40-24SMAZ |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |