Electronic Components Datasheet Search |
|
RBC-17-D48NB-C Datasheet(PDF) 3 Page - Murata Power Solutions Inc. |
|
RBC-17-D48NB-C Datasheet(HTML) 3 Page - Murata Power Solutions Inc. |
3 / 10 page Performance/Functional Specifications Input Voltage: Continuous 75 Volts Transient (100msec max.) 100 Volts Input Reverse-Polarity Protection None, see notes. Install external fuse. Output Current Current limited. Devices can withstand an indefinite output short circuit without damage. Storage Temperature –55 to +125°C Lead Temperature (soldering, 10 sec.) +280°C These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied. Absolute Maximum Ratings Typical at TA = +25°C under nominal input voltage and full-load conditions unless noted. Refer to required airflow and Derating curves for thermal specifications. [1] Input Input Voltage Range 36-75 Volts Recommended External Fuse 20 Amp fast blow Start-up Threshold 35V Undervoltage shutdown 33.5V Overvoltage shutdown None [note 12] Input Current, nominal See ording guide Input Current, VIN = VMIN 6.00A Input Current, shut-down mode 6.5mA max. Inrush Transient 0.05A2-seconds Reflected Ripple Current [2] 15mAp-p Internal Filter Type L-C Reverse Polarity Protection None (see note 11), install external fuse Remote On/Off Control [5] Positive Logic On = Open or +3.5 to +13.5 V. Off = Gnd. Pin or 0 to +1V. Negative Logic On = Gnd. Pin or 0 to +1V. Off = Pin open or +3.5V to +13.5V. Current 2mA max. Output Total Output Power [3] 210W max. [15] Setpoint Accuracy (50% load) ±3% of VNOMINAL Extreme Accuracy [14] 11.4V min. to 12.6V max. Output Current [7] See ordering guide Minimum Load No minimum load Ripple and Noise (20MHz bandwidth) See ordering guide Line and Load Regulation [10] See ordering guide Efficiency See ordering guide Isolation Voltage (Input/output) 2250Vdc min. (Input to baseplate) 1500Vdc min. (Baseplate to output) 1500Vdc min. Isolation Resistance 100M Isolation Capacitance 1500pF Isolation Safety Rating Basic Current Limit Inception (98% of VOUT) 27A, after warm up Short Circuit Current [6] 5 Amps (hiccup autorestart – remove short for recovery) Short Circuit Duration (+VOUT grounded) Continuous, no damage Overvoltage Protection 15Vdc max. via magnetic feedback Max. Capacitive Loading (resistive load) 10,000μF, low ESR 0.02 Ohms Temperature Coefficient ±0.02% per °C Dynamic Characteristics Dynamic Load Response 75μsec, 50-75-50% load step (to within 3% of VOUT) 100μsec, 25-75-25% load step Start Up Time (VIN to VOUT regulated) 60msec (Remote On to Vout regulated) 60msec Fixed Switching Frequency 225 ±25kHz Environmental Calculated MTBF [4] 1,247,727 hours Operating Case Temperature [13] +110°C max. Electronic Thermal Shutdown +125°C min. Operating Temperature Range -40ºC to +85ºC, See Derating curves (With Derating) Storage Temperature Range –55 to +125°C Flammability UL94V-0 Relative Humidity To 85% / +85°C Safety Compliance UL60950-1, CSA-C22.2 No.60950-1, IEC/EN60950-1 Electromagnetic Interference EN55022/CISPR22 conducted or radiated (may require external filters) Physical Pin Material Copper alloy with gold plate over nickel underplate Weight 1 ounce (28.4 grams) (1) All models are tested and specified with external 1 || 10uF ceramic/tantalum output capacitors and external 22uF input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test equipment and may not be required to achieve specified performance in your applications. All models are stable and regulate within spec under no-load conditions. General conditions for Specifications are +25°C, VIN = nominal, VOUT = nominal, full load. (2) Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is CIN = 33μF/100V tantalum, CBUS = 220μF/100V electrolytic, LBUS = 12μH. (3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total RMS current over time does not exceed the Derating curve. All Derating curves are presented at sea level altitude. Be aware of reduced power dissipation with increasing density altitude. (4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed conditions, TPCBOARD = +25°C, full output load, natural air convection. (5) The On/Off Control may be driven with external logic or by applying appropriate external voltages which are referenced to Input Common. The On/Off Control Input should use either an open collector/open drain transistor or logic gate which does not exceed +13.5V. (6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. (7) The outputs are not intended to sink appreciable reverse current. (8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise Reduction. (9) All models are fully operational and meet published specifications, including “cold start” at –40°C. (10) Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme. (11) If reverse polarity is accidentally applied to the input, a body diode will become forward biased and will accept considerable current. To ensure reverse input protection with full output load, always connect an external input fuse in series with the +VIN input. Use approximately twice the full input current rating with nominal input voltage. (12) Input overvoltage shutdown on 48V input models is normally deleted in order to comply with certain telecom reliability requirements. These requirements attempt continued operation despite significant input overvoltage. (13) Note that the converter may operate up to +110°C PCB temperature with the baseplate installed. However, thermal self-protection occurs near +125°C and there is a temperature gradient from high power components. Therefore, +100°C baseplate temperature is recommended to avoid thermal shutdown. (14) “Extreme accuracy” refers to all combinations of line and load regulation, output current, initial setpoint accuracy and temperature coefficient. (15) Vo = (11.64V to 12.36V) Power = (197.88W to 210.12W) RBC-12/17-D48 Series Quarter Brick, Regulated Bus Converters MDC_RBC-12/17-D48.B02 Page 3 of 10 www.murata-ps.com/support |
Similar Part No. - RBC-17-D48NB-C |
|
Similar Description - RBC-17-D48NB-C |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |