10 / 19 page AC specifications for U1272A Function Range Resolution Accuracy 45 to 65 Hz 20 Hz to 1 kHz 1 kHz to 5 kHz 5 kHz to 20 kHz 20 kHz to 100 kHz True RMS AC Voltage [1] 30 mV 0.001 mV 0.6 + 20 0.7 + 25 1.0 + 25 1.0 + 40 3.5 + 40 300 mV 0.01 mV 0.6 + 20 0.7 + 25 1.0 + 25 1.0 + 40 3.5 + 40 3 V 0.0001 V 0.6 + 20 1.0 + 25 1.5 + 25 2.0 + 40 3.5 + 40 30 V 0.001 V 0.6 + 20 1.0 + 25 1.5 + 25 2.0 + 40 3.5 + 40 300 V 0.01 V 0.6 + 20 1.0 + 25 1.5 + 25 2.0 + 40 - 1000 V 0.1 V 0.6 + 20 1.0 + 25 1.5 + 25 - - LPF (low pass filter) enabled, applicable for all voltage ranges and resolution 0.6 + 20 1.0 + 25 @ <200 Hz 5.0 + 25 @ <440 Hz -- - Z LOW 1000 V 2.0 + 40 2 + 40 @ <440 Hz -- - Function Range Resolution Accuracy Burden voltage/ Shunt 45 to 65 Hz 20 Hz to 2 kHz True RMS AC Current [2] 300 µA 0.01 µA 0.6 + 25 0.9 + 25 <0.04 V/ 100 Ω 3000 µA 0.1 µA 0.6 + 25 0.9 + 25 <0.4 V/ 100 Ω 30 mA 0.001 mA 0.6 + 25 0.9 + 25 <0.08 V/ 1 Ω 300 mA 0.01 mA 0.6 + 25 0.9 + 25 <1.00 V/ 1 Ω 3A 0.0001 A 0.8 + 25 1.0 + 25 <0.1 V/ 0.01 Ω 10 A 0.001 A 0.8 + 25 1.0 + 25 <0.3 V/ 0.01 Ω 1. Notes for voltage specifications • Overload protection: 1000 Vrms. For millivolt measurements, 1000 Vrms for short circuits with <0.3 A current. • Input impedance: 10 MΩ (nominal) in parallel with <100 pF. • Z LOW impedance: 2 kΩ (nominal) • The input signal is lower than the product of 20,000,000 V×Hz. • For 20 to 100 kHz accuracy: Three counts of the LSD per kHz of additional error is to be added for frequencies >20 kHz and signal inputs <10% of range. 2. Notes for current specifications • Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse • Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse • Specification for 300 mA range: 440 mA continuous. • Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals >10 to 20 A for 30 seconds maximum. After measuring currents >10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low current measurements. 10 |
Similar Part No. - U1270 |
|
Similar Description - U1270 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |