  E3X-DA8AT-S Datasheet HTML 1Page - Omron Electronics LLC E3X-DA8AT-S Datasheet HTML 2Page - Omron Electronics LLC E3X-DA8AT-S Datasheet HTML 3Page - Omron Electronics LLC E3X-DA8AT-S Datasheet HTML 4Page - Omron Electronics LLC E3X-DA8AT-S Datasheet HTML 5Page - Omron Electronics LLC E3X-DA8AT-S Datasheet HTML 6Page - Omron Electronics LLC E3X-DA8AT-S Datasheet HTML 7Page - Omron Electronics LLC E3X-DA8AT-S Datasheet HTML 8Page - Omron Electronics LLC E3X-DA8AT-S Datasheet HTML 9Page - Omron Electronics LLC Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 34 page
background image
In addition to our unique APC circuit used in the
E3X-DA-N Amplifiers to compensate for the dete-
rioration of the LED, the E3X-DA-S uses 4-ele-
ment LEDs to counteract the deterioration of the
light-emitting elements over time and achieve the
industry's most stable long-term detection perfor-
mance.
Furthermore, the circuit is designed with excess
light capacity, so the Sensors can be used with
high stability regardless of whether the APC cir-
cuit is ON or OFF.
With the Twin-output Amplifiers, output 2 can function as an
alarm output (light level operation) to indicate when the light
level has changed due to dirt or other causes.
Time
Time
OMRON provides the industry's most stable long-term detection
by using new 4-element LEDs and an APC (Auto Power Control) circuit.
Time
Without APC circuit
Without APC circuit
3-element LED and APC
4-element LED and APC
Earlier Method
New Method
Time
Light Level Operation
(Normal Operation)
Judges light level changes by comparing
the incident level and threshold level.
Differential Operation
Judges light level changes by comparing the
incident level to a time-averaged incident level.
Threshold level
(absolute value)
Light level difference
(absolute value)
Incorrect operation due to light level change
The light level varies due to dirt, temperature
variations, or other environmental factors.
Detecting differences in the light level enables
setting more subtle light level differences.
Incident
level
Incident
level
Output
ON
OFF
Time
Time
2000
1000
Threshold 1
Threshold 2
The counter function can output signal after counter
counts up or down.
(Advanced External-input Models)
Counter Function
Highest Level of Stability
Stable, Long-term Performance with OMRON's APC Function
Many Advanced Functions for Even More Applications
Patent Pending
Patent Pending
Incorrect operation
Minute changes are
detected reliably.
Area output function can be
used for range judgement.
(Advanced Twin-output Models)
Remote input function can control the Sensor remotely.
(Advanced External-input Models)
Provides high-speed response for miniature workpieces, such as chip parts and devices with short tact times.
Operations that required multiple Sensors, such as
height measurement, can be performed with just one
Sensor. Two threshold levels can be set to easily output
within-range and out-of-range outputs.
A counter function is built-in, so the number
of workpieces can be counted without a sep-
arate counter or small PLC that used to be
required.
Input signals can make various remote settings, such as teaching operations, power tuning, and emitter
OFF. This model is ideal for diverse needs, such as checking Sensor operation remotely before operation
or making settings remotely because teaching has to be performed often for frequent workpiece model
changes.
Fastest in the Industry
Three kinds of timer functions are supported. The timers can be set between 1 ms and 5 s.
A one-shot timer is supported in addition to the ON-delay and OFF-delay timers.
The Amplifier's ON time can be fixed, which is useful during high-speed workpiece detection.
Discriminating Tablet Lengths
Detecting Seals
Detecting Leads on Electronic Parts
Detecting Chip Components
6
7
This operation mode uses a special OMRON algorithm to compensate for slight light level changes
due to dirt or temperature variations and detect only the light level changes due to the workpiece.
Area output
Incident
level
Time
Counter
Time
Up Counter
Down Counter
Counter
Counter
value
Time
Threshold
level
Output when count reaches SV.
Output when count reaches 0.
Alarm output
threshold
Alarm output
Long-term stability
Slight light level changes can be detected with stability and
precision, eliminating the need for time-consuming manual ad-
justments for light level changes.
Compensate for the effects of contaminants and temperature variation
with differential operation mode. (Advanced Models)
Detecting marks in a dusty environment
Detecting knots in thread


Similar Part No. - E3X-DA8AT-S

ManufacturerPart #DatasheetDescription
logo
Omron Electronics LLC
E3X-DA8AT-S OMRON-E3X-DA8AT-S Datasheet
5Mb / 35P
   Evolution and Perfection The next-generation platform for a wide range of sensing
More results

Similar Description - E3X-DA8AT-S

ManufacturerPart #DatasheetDescription
logo
List of Unclassifed Man...
FS-V21 ETC1-FS-V21 Datasheet
416Kb / 4P
   DUAL DIGITAL FIBER SENSOR
FX-300 ETC-FX-300 Datasheet
13Mb / 28P
   Digital Fiber Sensor
logo
FOTEK CONTROLS CO., LTD...
FF-03R FOTEK-FF-03R Datasheet
1,019Kb / 4P
   OPTICAL FIBER SENSOR
logo
Pepperl+Fuchs Inc.
MLV41-LL-IR-2133 PF-MLV41-LL-IR-2133 Datasheet
281Kb / 2P
   Fiber optic sensor for glass fiber optics
OJ500-M1K-E23 PF-OJ500-M1K-E23 Datasheet
220Kb / 3P
   Fiber optic sensor for glass fiber optics
MLV41-LL-IR-1347 PF-MLV41-LL-IR-1347 Datasheet
281Kb / 2P
   Fiber optic sensor for glass fiber optics
MLV41-LL-RT-2492 PF-MLV41-LL-RT-2492 Datasheet
269Kb / 2P
   Fiber optic sensor for glass fiber optics
logo
Omron Electronics LLC
E3XA51 OMRON-E3XA51 Datasheet
205Kb / 17P
   Fiber-Optic Photoelectric Sensor
logo
Pepperl+Fuchs Inc.
MLV41-LL-IR-2492 PF-MLV41-LL-IR-2492 Datasheet
269Kb / 2P
   Fiber optic sensor for glass fiber optics
logo
FOTEK CONTROLS CO., LTD...
VF-06R FOTEK-VF-06R Datasheet
1,023Kb / 2P
   Twin trimmer Fiber sensor
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.NET
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com