Electronic Components Datasheet Search |
|
CCH600PS24 Datasheet(PDF) 1 Page - XP Power Limited |
|
CCH600PS24 Datasheet(HTML) 1 Page - XP Power Limited |
1 / 2 page Notes 1. Safety approvals cover frequency 47-63 Hz. Specification 400/600 Watts • Baseplate Cooled • High Efficiency up to 90% • 40 °C to +70 °C Operation • Industrial & MIL STD461E EMC Compliance • Power Fail, Inhibit, Overtemp & Current Share • 5V Standby Output • 3 Year Warranty CCH400 600 Series Input Input Voltage • 90-264 VAC Input Frequency • 47-400 Hz(1) Input Current • CCH400: 4.3/2.1 A typ. at 115/230 VAC, CCH600: 6.3/3.1 A typ. at 115/230 VAC, full load Inrush Current • 60 A max at 230 VAC, 25 °C cold start Power Factor • >0.9 Earth Leakage Current • 0.7/1.1 mA at 115/230 VAC at 60/50 Hz Input Protection • Internal F10 A/250 V fuse Output Output Voltage • 12-48 VDC Output Voltage Trim • ±10% Initial Set Accuracy • ±1% V1, ±3% V2 Minimum Load • No minimum load required Start Up Delay • Typically 1 s Start Up Rise Time • 50 ms typical Hold Up Time • 20 ms min Drift • ±0.2% after 20 min warm up Line Regulation • ±0.5% max Load Regulation • ±1% V1, ±5% V2 max Over/Undershoot • 1% typical Transient Response • 4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change Ripple & Noise • Typically 1% pk-pk V1, V2 2%, 20 MHz bandwidth Overvoltage Protection • 110-140% Vnom, recycle input to reset Overload Protection • 105-140% V1 only Short Circuit Protection • Continuous, approximately constant current Temperature • 0.05%/˚C Coefficient Overtemp. Protection • Fitted Remote Sense • Compensates for 0.5 V total voltage drop Remote On/Off • Uncommitted isolated optocoupler diode, powered diode inhibits V1 xppower.com General Efficiency • 89% typical Isolation • 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground Switching Frequency • 30-333 kHz PFC, 51.1 kHz main and 138 kHz standby converter Signals • Power Fail, Inhibit, Current Share, Overtemperature Warning and 5 V Standby MTBF • 300 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • -40 ˚C to +70 ˚C ambient. Baseplate must be maintained ≤+85 °C, see thermal considerations Cooling • Baseplate, conduction cooling Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 ˚C to +85 ˚C Operating Altitude • 3000 m Shock • MIL-STD 810F Clause 516.5 proc 1 Vibration • MIL-STD 810F figure 514.5C-17 EMC & Safety Low Voltage PSU EMC • EN61204-3, high severity level Emissions • EN55022 level B conducted, level A radiated, MIL-STD 461D-F, CE102 Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, installation class 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A, MIL-STD 461 CS114 Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals • IEC60950-1 CB report, UL60950-1, TUV EN60950-1 Equipment Protection • Class I Class |
Similar Part No. - CCH600PS24 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |