7 / 12 page Remote Fuse Monitoring Accessory CH-PLC Specifications: • Power Input: 24Vdc / 5mA • Sensing Voltage: 600V/30mA • Output Signals: Digital 0Vdc (Low), 24Vdc (High) - 0Vdc Low – Fuse is good - 24Vdc High – Fuse has opened When the fuse opens, the output signal is sent high and will remain high until the unit is reset • Rated Impulse Voltage: 8kV • Local Indication: Two distinct LEDs indicate unit power (green) and open fuse (red). Upon the replacement of the fuse, the actuation of the reset switch will reset the open fuse LED • Flammability Rating: UL 94V0 Wiring: • For power, signal and ground connections use 22-24AWG (0.25mm2) 300V rated wire Emissions and Immunity Testing: • Electrostatic Discharge IEC 61000-4-2 • Electrical Fast Transient/Burst IEC 6100-4-4 • Surge Immunity IEC61000-4-5 Packaging: • The CH-PLC is packaged individually • A single unit monitors up to three phases • Package includes 0.11” (2.8mm) quick connects for power, signal and ground connections Minimum Circuit Voltage: • Minimum circuit voltage required across the CH holder is 100Vac for the remote indication device to operate Installation Technique: • Mounts on the left side of the fuse holder and mechanically interlocks with the fuse holder switch handle with hardware provided IP20 Rating: Yes Environmental Data: • Storage and Operating Temperature: -20°C to 75°C Agency Information: • UL 508 • cULus to CSA Standard 22.2 No.14 PLC Programming: • The CH-PLC signal line is designed to provide a digital input to a PLC I/O card. • Programmable Logic Control program must be written to properly interpret the input signal to the PLC. • The PLC program should check for consecutive high signals before taking action on a critical process. De-energize all circuits before installing or removing any CH-PLC devices and follow all prescribed safety procedures. Make it Simple with Cooper Bussmann resettable three-phase remote fuse monitor that integrates with a Programmable Logic Controller (PLC) or other monitoring and control equipment. |
Similar Part No. - BB1P100M15 |
|
Similar Description - BB1P100M15 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |