2 / 8 page HIH-4030/31 Series 2 www.honeywell.com/sensing TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.) Parameter Minimum Typical Maximum Unit Specific Note Interchangeability (first order curve) – – – – – 0% RH to 59% RH -5 – 5 % RH – 60% RH to 100% RH -8 – 8 % RH – Accuracy (best fit straight line) -3.5 – +3.5 % RH 1 Hysterisis – 3 – % RH – Repeatability – ±0.5 – % RH – Settling time – – 70 ms – Response time (1/e in slow moving air) – 5 – s – Stability (at 50% RH in a year) – ±1.2 – % RH 2 Stability (at 50% RH in a year) – ±0.5 – % RH 3 Voltage supply 4 – 5.8 Vdc 4 Current supply – 200 500 μA – Voltage output (1 st order curve fit) V OUT=(VSUPPLY)(0.0062(sensor RH) + 0.16), typical at 25 ºC Temperature compensation True RH = (Sensor RH)/(1.0546 – 0.00216T), T in ºC Output voltage temp. coefficient at 50% RH, 5 V – -4 – mV/ºC – Operating temperature -40[-40] See Figure 1. 85[185] ºC[ºF] – Operating humidity (HIH-4030) 0 See Figure 1. 100 % RH 5 Operating humidity (HIH-4031) 0 See Figure 1. 100 % RH – Storage temperature -50[-58] – 125[257] ºC[ºF] – Storage humidity See Figure 2. % RH 5 Specific Notes: 1. Can only be achieved with the supplied slope and offset. For HIH-4030/31-003 catalog listings only. 2. Includes testing outside of recommended operating zone. 3. Includes testing for recommended operating zone only. 4. Device is calibrated at 5 Vdc and 25 ºC. 5. Non-condensing environment. When liquid water falls on the humidity sensor die, output goes to a low rail condition indicating no humidity. General Notes: • Sensor is ratiometric to supply voltage. • Extended exposure to >90% RH causes a reversible shift of 3% RH. • Sensor is light sensitive. For best performance, shield sensor from bright light. FACTORY CALIBRATION DATA HIH-4030/31 Sensors may be ordered with a calibration and data printout. See Table 2 and the order guide on the back page. TABLE 2. EXAMPLE DATA PRINTOUT Model HIH-4030-003 Channel 92 Wafer 030996M MRP 337313 Calculated values at 5 V V OUT at 0% RH V OUT at 75.3% RH 0.958 V 3.268 V Linear output for 3.5% RH accuracy at 25 °C Zero offset Slope Sensor RH 0.958 V 30.680 mV/%RH (V OUT - zero offset)/slope (V OUT - 0.958)/0.0307 Ratiometric response for 0% RH to 100% RH V OUT V SUPPLY (0.1915 to 0.8130) |
Similar Part No. - HIH-4030-001S |
|
Similar Description - HIH-4030-001S |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |