5 / 9 page 235 Text 234 Text Surface-Mounting Signal Relay – G6S Maximum Switching Power Single-winding Latching Double-winding Latching Switching voltage (V) Ambient temperature ( °C) Ambient Temperature vs. Maximum Coil Voltage Single-side Stable Ambient temperature ( °C) G6SU G6SK 12 VDC max. G6SK 24 VDC AC resistive load DC resistive load 12 VDC max. 24 VDC (G6S-Y, 12 VDC max.) Reference Data Ambient Temperature vs. Switching Current Single-side Stable Single-winding Latching Double-winding Latching Ambient temperature ( °C) G6SU 12 VDC max. G6SU 24 VDC G6SK 12 VDC max. G6SK 24 VDC Ambient temperature ( °C) 12 VDC max. 24 VDC (G6S-Y) 24 VDC (G6S-Y, 12 VDC max.) 24 VDC (G6S-Y) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Engineering Data Soldering Preheating Upper surface of case (peak): 255∞C max. 120 max. 30 max 250 max. 230 180 150 Relay terminal section Soldering Preheating 220 to 245 180 to 200 150 90 to 120 20 to 30 Temperatures indicate the surface temperatures of the PCB. • The thickness of cream solder to be applied should be within a range between 150 and 200 µm on OMRON’s recommended PCB pattern. • In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left side. Note: The temperature profile indicates the temperature of the relay terminal section. Recommended Soldering Method 1. IRS Method (Mounting solder: Lead) 2. IRS Method (Mounting solder: Lead-free) Time (s) Time (s) Surface-Mounting Signal Relay – G6S Model Contact form Coil ratings Contact ratings G6S-2, G6S-2F, G6S-2G DPDT 1.5 to 48 VDC G6SU2, G6SK-2, G6SU-2F 1.5 to 24 VDC G6SU2G, G6SK-2F, G6SK-2G ■ Approved Standards UL (File No. E41515)/CSA C22.2 (File No. LR24825) 2 A, 30 VDC 0.3 A, 110 VDC 0.5 A, 125 VAC Model Contact form Isolation category Voltage G6S-2-Y, G6S-2G-Y, G6S-2F-Y DPDT Supplementary Isolation 250 VAC EN60950 ■ Characteristics Contact resistance (Note) 75 mΩ max. Operate (set) time (Note 2) 4 ms max. (mean value: approx. 2.5 ms; latching type: approx. 2 ms) Release (reset) time (Note 2) 4 ms max. (mean value: approx. 1.5 ms; latching type: approx. 2 ms) Max. operating frequency Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance (Note 3) 1,000 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between coil and contacts (double-winding latching) 1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 500 VAC, 50/60 Hz for 1 min between set and reset coil (double-winding latching) Impulse withstand voltage 2,500 V (2 x 10 µs) between coil and contacts 1,500 V (10 x 160 µs) between coil and contacts (double-winding latching) 2,500 V (2 x 10 µs) between contacts of different polarity 1,500 V (10 x 160 µs) between contacts of same polarity (conforms to FCC Part 68) Vibration resistance Destruction: 10 to 55 to 10 Hz, 2.5mm single amplitude (5mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 1.65mm single amplitude (3.3mm double amplitude) Shock resistance Destruction: 1,000 m/s2 (approx. 100G) Malfunction: 750 m/s2 (approx. 175G) Endurance Mechanical: 100,000,000 operations min. (at 36,000 operations/hr) Electrical: 100,000 operations min. (2 A at 30 VDC, resistive load: 1,200 operations/hr) 100,000 operations min. (0.5 A at 125 VAC, resistive load) Ambient temperature Operating: -40˚C to 85˚C (with no icing), -40˚C to 70˚C (double-winding latching, 24 VDC) Ambient humidity Operating: 5% to 85% Weight Approx. 2 g Note: The above values are initial values. Note: 1. The contact resistance was measured with 10mA at 1 VDC with a voltage drop method. Note: 2. Values in parentheses are actual values. Note: 3. The insulation resistance was measured with a 500-VDC megohmeter applied to the same parts as those used for checking the dielectric strength (except between the set and reset coil). Omron 08 Cat 1-302 5/10/07 15:39 Page 234 |
Similar Part No. - G6SK-2F-Y4.5VDC |
|
Similar Description - G6SK-2F-Y4.5VDC |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |