3 / 7 page 175 G6B G6B ■ Contact Ratings Note: P level: λ 60 = 0.1 x 10 -6/operation ■ Characteristics Note: The data shown above are initial values. Item SPST-NO SPST-NO + SPST-NC, DPST-NO, DPST-NC Load Resistive load (cos φ = 1) Inductive load (cos φ = 0.4; L/R = 7 ms) Resistive load (cos φ = 1) Inductive load (cos φ = 0.4; L/R = 7 ms) Rated load 5 A at 250 VAC; 5A at 30 VDC 2 A at 250 VAC; 2 A at 30 VDC 5 A at 250 VAC; 5A at 30 VDC 1.5 A at 250 VAC; 1.5 A at 30 VDC Contact material Ag Alloy (Cd free) Rated carry current 5 A Max. switching voltage 380 VAC, 125 VDC Max. switching current 5 A Max. switching power 1,250 VA, 150 W 500 VA, 60 W 1,250 VA, 150 W 375 VA, 80 W Failure rate (reference value) 10 mA at 5 VDC Item SPST-NO (High-capacity) Load Resistive load (cos φ = 1) Inductive load (cos φ = 0.4; L/R = 7 ms) Rated load 8 A at 250 VAC; 8 A at 30 VDC 2 A at 250 VAC; 2 A at 30 VDC Contact material Ag Alloy (Cd free) Rated carry current 8 A Max. switching voltage 380 VAC, 125 VDC Max. switching current 8 A Max. switching power 2,000 VA, 150 W Failure rate (reference value) 10 mA at 5 VDC Contact resistance 30 m Ω max. Operate (set) time 10 ms max. (mean value: 1-pole approx. 3 ms, 2-pole approx. 4 ms) Release (reset) time Single-side stable types: 10 ms max. (mean value: 1-pole approx. 1 ms, 2-pole approx. 2 ms) Latching types: 10 ms max. (mean value: approx. 3 ms) Min. set/reset signal width Latching type: 15 ms min. (at 23°C) Max. operating frequency Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 M Ω min. (at 500 VDC, at 250 VDC between set coil and reset coil) Dielectric strength 3,000 VAC (Latching types: 2,000 VAC), 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 250 VAC, 50/60 Hz for 1 min between set and reset coils 2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance Destruction: 1,000 m/s2 Malfunction: Single-side stable: 100 m/s2; Latching: 300 m/s2 Endurance Mechanical: 50,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operation min. (at 1,800 operations/hr) Ambient temperature Operating: −25°C to 70°C (with no icing) Ambient humidity Operating: 5% to 85% Weight Double-winding latching: Approx. 3.7 g High-capacity: Approx. 4.6 g Double pole: Approx. 4.5 g Other: Approx. 3.5 g |
Similar Part No. - G6BU-2074PUSP6B12VDC |
|
Similar Description - G6BU-2074PUSP6B12VDC |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |