Electronic Components Datasheet Search |
|
HE1AN-P-DC12V-H18 Datasheet(PDF) 2 Page - Panasonic Semiconductor |
|
HE1AN-P-DC12V-H18 Datasheet(HTML) 2 Page - Panasonic Semiconductor |
2 / 5 page Panasonic Corporation 2013 © Panasonic Corporation Automation Controls Buisiness Division industrial.panasonic.com/ac/e/ HE PV Type –2– ASCTB101E 201307-T TYPES Standard packing: Carton: 20 pcs.; Case: 100 pcs. *Standard 6V, 12V and 24V DC type: Certified by UL/C-UL (Standard 9V type: Certified by UL/C-UL and VDE) RATING 1. Coil data 2. Specifications Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *3. Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage. *4. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. *5. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions. Nominal coil voltage Standard type* High capacity type Part No. Part No. 6V DC HE1aN-P-DC6V-H18 HE1aN-P-DC6V-Y5 9V DC HE1aN-P-DC9V-H18 HE1aN-P-DC9V-Y5 12V DC HE1aN-P-DC12V-H18 HE1aN-P-DC12V-Y5 24V DC HE1aN-P-DC24V-H18 HE1aN-P-DC24V-Y5 Nominal coil voltage Pick-up voltage (at 20 °C 68°F) (Initial) Drop-out voltage (at 20 °C 68°F) (Initial) Nominal operating current [ ±10%] (at 20°C 68°F) Coil resistance [ ±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 20 °C 68°F) 6V DC 70%V or less of nominal voltage 10%V or more of nominal voltage 320mA 18.8 Ω 1,920mW 110%V of nominal voltage 9V DC 213mA 42.2 Ω 12V DC 160mA 75.0 Ω 24V DC 80mA 300.0 Ω Characteristics Item Specifications Standard type High capacity type Contact Arrangement 1 Form A Contact resistance (Initial) Max. 100 m Ω (By voltage drop 6 V DC 1A) Contact material AgSnO2 type AgNi type Rating Nominal switching capacity 35 A 250 V AC (Resistive load) 48 A 250 V AC (Resistive load) Contact carring power 8,750 VA (Resistive load) 12,000 VA (Resistive load) Max. switching voltage 250 V AC Max. switching current 35 A (AC) 48 A (AC) Nominal operating power 1,920 mW Min. switching capacity (Reference value)*1 100 mA 5 V DC Electrical characteristics Insulation resistance (Initial) Min. 1,000M Ω (at 500V DC) Measurement at same location as “Breakdown voltage” section. Breakdown voltage (Initial) Between open contacts 2,000 Vrms for 1 min. (Detection current: 10 mA) Between contact and coil 5,000 Vrms for 1 min. (Detection current: 10 mA) Surge breakdown voltage*2 (Between contact and coil) (Initial) 10,000 V Temperature rise Max. 60 °C 140°F (By resistive method, contact carrying current: 35A, 100%V of nominal coil voltage at 55 °C 131°F.) Max. 60 °C 140°F (By resistive method, contact carrying current: 48A, 100%V of nominal coil voltage at 55 °C 131°F.) Max. 30 °C 86°F (By resistive method, contact carrying current: 35A, 60%V of nominal coil voltage at 85 °C 185°F.) Max. 30 °C 86°F (By resistive method, contact carrying current: 48A, 60%V of nominal coil voltage at 85 °C 185°F.) Coil hold voltage*3 40 to 100%V (Contact carrying current: 35A, at 20 °C 68°F), 50 to 100%V (Contact carrying current: 35A, at 55 °C 131°F), 50 to 60%V (Contact carrying current: 35A, at 85 °C 185°F) 40 to 100%V (Contact carrying current: 48A, at 20 °C 68°F), 50 to 100%V (Contact carrying current: 48A, at 55 °C 131°F), 50 to 60%V (Contact carrying current: 48A, at 85 °C 185°F) Operate time (at 20 °C 68°F) Max. 30 ms (nominal coil voltage, excluding contact bounce time) Release time (at 20 °C 68°F)*5 Max. 10 ms (nominal coil voltage, excluding contact bounce time) (without diode) Mechanical characteristics Shock resistance Functional Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 µs.) Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 µs.) Destructive 10 to 55 Hz at double amplitude of 1.5 mm Expected life Mechanical Min. 106 (at 180 times/min.) Electrical Resistive load Min. 3 ×104 (35 A 250 V AC) (ON : OFF = 1s : 9s) Min. 3×104 (48 A 250 V AC) (ON : OFF = 1s : 9s) Inductive load — Endurance: 48 A 250 V AC (cos φ = 0.8), Min. 3 ×104 (ON : OFF = 0.1s : 10s) Overload: 72 A 250 V AC (cos φ = 0.8), Min. 50 (ON : OFF = 0.1s : 10s) Conditions Conditions for operation, transport and storage*4 Ambient temperature: –50 to +55 °C –58 to +131°F (When nominal coil voltage applied) –50 to +85 °C –58 to +185°F (When applied coil hold voltage is 50% to 60% of nominal coil voltage) Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature); Atmospheric pressure: 86 to 106 kPa Max. operating speed 6 times/min. (at nominal switching capacity ON : OFF = 1s : 9s) Unit weight Approx. 80 g 2.82 oz |
Similar Part No. - HE1AN-P-DC12V-H18 |
|
Similar Description - HE1AN-P-DC12V-H18 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |