Back Button SV01A103AEA01R00 Datasheet HTML 3Page - Murata Manufacturing Co., Ltd. SV01A103AEA01R00 Datasheet HTML 4Page - Murata Manufacturing Co., Ltd. SV01A103AEA01R00 Datasheet HTML 5Page - Murata Manufacturing Co., Ltd. SV01A103AEA01R00 Datasheet HTML 6Page - Murata Manufacturing Co., Ltd. SV01A103AEA01R00 Datasheet HTML 7Page - Murata Manufacturing Co., Ltd. SV01A103AEA01R00 Datasheet HTML 8Page - Murata Manufacturing Co., Ltd. SV01A103AEA01R00 Datasheet HTML 9Page - Murata Manufacturing Co., Ltd. SV01A103AEA01R00 Datasheet HTML 10Page - Murata Manufacturing Co., Ltd. SV01A103AEA01R00 Datasheet HTML 11Page - Murata Manufacturing Co., Ltd. Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 23 page
background image
SV03 Series Specifications and Test Methods
9
Rotational Life
The adjustment rotor should be continuously rotated within ±160° of effective electrical rotational angle, at the rate of 3 cycle for 1
second for 300 thousands cycles under the condition of 25±2°C of temperature without loading.
Then, the rotary position sensor should be kept in the dry box for 10±5 minutes.
8
Low Temp.
Exposure
The rotary position sensor should be stored in a chamber at a temperature of -40±3°C without loading for 1000±8 hours.
After removing from the chamber, the rotary position sensor should be kept in the dry box for 1 to 2 hours.
7
High Temp.
Exposure
The rotary position sensor should be stored in a chamber at a temperature of 125±2°C without loading for 1000±8 hours.
After removing from the chamber, the rotary position sensor should be kept in the dry box for 1 to 2 hours.
6
Humidity Load Life
Full rated continuous working voltage not exceeding 5Vdc should be applied intermittently between terminal #1 and terminal #3 of the
rotary position sensor, 1.5 hours on and 0.5 hours off, for 1000±8 hours in total in a chamber at a temperature of 85±3°C and relative
humidity of 85±5%. After removing from the chamber, the rotary position sensor should be kept in the dry box for 5±1/6 hours.
5
Shock
The rotary position sensor should be applied the following shock test: Half sine wave with the peak acceleration 14,700m/s2
(1,500G) max. can be applied in each 3 times (total 18 times) in the 3 direction of x, y, and z with bidirectional.
Then, the rotary position sensor should be kept in the dry box for 1 to 2 hours.
4
Vibration
The rotary position sensor should be log-sweeped by the sine oscillatory wave of the maximum amplitude 1.5mm, Acceleration
98m/s2 (10G) under the condition of the vibrational frequency between 10Hz and 2kHz. In 1 cycle which is vibrated for each 20
minutes in the 3 direction of x, y, and z., 12 cycles should be applied during 12 hours in total.
Then, the rotary position sensor should be kept in the dry box for 1 to 2 hours.
3
Humidity
The rotary position sensor should be stored in a chamber at temperature of +85±3°C and relative humidity of 85±5% for 1000±8
hrs. After removing from the chamber, the rotary position sensor should be kept in the dry box for 24 +8/-0 hours.
2
Temperature Cycle
(Thermal Shock)
The rotary position sensor should be subjected to Table 2 temperature for 5 cycles.
Then, the rotary position sensor should be kept in the dry box for 24 +8/-0 hrs.
1
Linearity
Linearity should be specified a deviation with the below ideal straight line, between ±160° from the index point which is 50% of out
put voltage.
The ideal straight line has 100%/333.3° as taper and pass the above index point.
Measurement is performed using the following measurement circuit, and the rotor should be rotated to clockwise direction.
No.
Test Methods
Item
The tests and measurements should be conducted under the condition of 15 to 35°C of temperature 25 to 75% of relative humidity and 86 to 106 kpa of
atmospheric pressure unless otherwise specified. If questionable results occur that have been measured in accordance with the above mentioned conditions,
the tests and measurements should be conducted under the condition of 25±2°C of temperature, 45 to 55% of relative humidity and 86 to 106 kpa of
atmospheric pressure. When the potentiometer is tested after soldering on PCB, it should be tested after being kept in a room (15 to 35°C, 25 to 75%RH)
over 24 hours except "Resistance to soldering heat".
GND (#1)
Connection Impedance: 1M ohm min.
DC5V (#3)
Output (#2)
Guarantee limit for linearity
100%
50%
100% / 333.3°
-160°
+160°
0%
CW
CCW
Rotational Angle (°)
Output Voltage Ratio (%)
V (1-2)
V (1-3)
X100
1
Sequence
-40±3
30
2
Shift Time
5 max.
3
+125±3
30
4
Shift Time
5 max.
Temperature (°C)
Time (min.)
Table 2: One cycle of temperature cycle
R51E.pdf
Mar.1,2013
5
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
1


Similar Part No. - SV01A103AEA01R00

ManufacturerPart #DatasheetDescription
logo
Murata Manufacturing Co...
SV01A103AEA01B00 MURATA-SV01A103AEA01B00 Datasheet
195Kb / 3P
   Leaded terminal type is available
More results

Similar Description - SV01A103AEA01R00

ManufacturerPart #DatasheetDescription
logo
Murata Manufacturing Co...
R51E MURATA-R51E Datasheet
729Kb / 26P
   Rotary Position Sensors
logo
Honeywell Solid State E...
RTY360LVNAX HONEYWELL-RTY360LVNAX Datasheet
1Mb / 10P
   Hall-effect Rotary Position Sensors
logo
ALPS ELECTRIC CO.,LTD.
RDC40 ALPS-RDC40_15 Datasheet
2Mb / 6P
   Rotary sensors catering to diverse position detection needs
logo
TT Electronics.
PHS04 TTELEC-PHS04 Datasheet
663Kb / 3P
   Rotary Position Sensor
PHS11 TTELEC-PHS11 Datasheet
439Kb / 3P
   Rotary Position Sensor
logo
Murata Manufacturing Co...
FR05CM21AR MURATA-FR05CM21AR Datasheet
191Kb / 8P
   Rotary Sensors
logo
Melexis Microelectronic...
MLX90340 MELEXIS-MLX90340 Datasheet
1Mb / 42P
   Absolute Rotary Position Sensor
logo
SICK AG
MPA-503THTU0 SICK-MPA-503THTU0 Datasheet
1Mb / 6P
   POSITION SENSORS
MPS-128TLTQ0 SICK-MPS-128TLTQ0 Datasheet
2Mb / 7P
   POSITION SENSORS
MPA-863THTP0 SICK-MPA-863THTP0 Datasheet
2Mb / 7P
   POSITION SENSORS
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.NET
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com