Electronic Components Datasheet Search |
|
USCLSXXXR1AVLTX Datasheet(PDF) 2 Page - List of Unclassifed Manufacturers |
|
USCLSXXXR1AVLTX Datasheet(HTML) 2 Page - List of Unclassifed Manufacturers |
2 / 12 page 2 Specifications are subject to change without notice USCDS0407063 USC Analogue inputs Measuring module BQ LSX module 1, mA and V DC/AC BQ LSE/LSF module 1, mA and V DC/AC + AUX BQ HSX module 1, A and V DC/AC BQ TRX module 1, temperature BQ TRX module 1, resistance Digital inputs (CMD) Incl. in the measuring module Number of inputs 1 (voltage-free) Use Reset of latch alarms Contact reading signal BQ xxx: <0.1mA, <3.5V DC BQ LSE/LSF: <2.5mA, <14V DC Close contact resistance Max 1k Ω Open contact resistance Min 500k Ω Insulation Non-insulated Accuracy (RS485) See table “Measuring accuracy”, temperature drifts and minimum-maximum indications” Additional errors Humidity 0.3% RDG, 60% to 90% R.H. Input frequency 0.4% RDG, 62 to 440 Hz Magnetic field 0.5% RDG @ 400 A/m Temperature drift See table “Measuring accuracy, temperature drifts and maximum minimum indications” Sampling rate BQ LSX module 500 samples/s @ 50Hz BQ LSE/LSF module 500 samples/s @ 50Hz BQ HSX module 500 samples/s @ 50Hz BQ TRX module 500 samples/s @ 50Hz Measurement updating 200 msec @ 50 Hz Resolution of measurements 10.000 points (4-dgt) Max. and min. indications See table “Measurement accuracy, temperature drifts and max min indications” Measurements Current, voltage, tempera- ture and resistance. For the current and voltage mea- surements: TRMS measure- ment of distorted sine waves. Coupling Direct. Crest factor ≤3; A Pmax=1,7In; VPmax=1,7Un Input impedance See table “input impedances and overloads” Frequency 40 to 440 Hz Overload See table “input impedances and overloads” Compensation Only temperature measurement module. RTD - For Pt 100-250-500-1000, 3-wire connection: up to 10 Ω - For resistance measur. with 20 Ω range: up to max 0.1Ω - For resistance measurements with ≥200Ωrange:uptomax10Ω TC Internal cold junction, within temperature range from 0 to +50°C. Automatic or manual compensation from 0 to 50°C. Input Specifications AUXILIARY DIGITAL INPUTS (FUTURE FUNCTION) ALARM OUTPUTS COMMUNICATION POWER SUPPLY INTERNAL BUS MEASURING INPUTS + DIGITAL INPUTS + AUXILIARY POWER SUPPLY Measuring inputs: DC/AC: mA-mV-V DC/AC: A-V °C/°F: TC-Pt-Ni- Ω Digital input: Alarm reset Auxiliary power supply: 13V / 50mA DC 25V / 25mA CC Remote programming by means of PC 90 to 260V AC/DC 18 to 60V AC/DC Analogue outputs: 1 x 20mA/10V DC Serial ports: RS485 RS232 1 alarm 2 alarms 4 alarms USC architecture |
Similar Part No. - USCLSXXXR1AVLTX |
|
Similar Description - USCLSXXXR1AVLTX |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |