Electronic Components Datasheet Search |
|
KX500-F5F Datasheet(PDF) 2 Page - C&D Technologies |
|
KX500-F5F Datasheet(HTML) 2 Page - C&D Technologies |
2 / 4 page KX500 8/99 REV B Page 2 Remote Sense Remote Sense is provided on Output #1 and will compensate for 0.3V of line drop. Remote Sense leads are protected against open, short, and reversal. Remote On/Off The power supply is turned on with a TTL logic level ‘1’ (or open) signal and turned off by a switch closure or TTL logic level ‘0’ referenced to (-) sense terminal. Consult the factory for other options. Over Voltage Protection Output #1: 6.25V, ±0.75 VDC. Output #2: 14.0V ±1VDC. (Output #2 12V) 17.0V ±1VDC. (Output #2 15V) The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Reverse Voltage Protection All outputs are protected to rated load. Transient Response The peak output voltage excursion on the main output will not exceed 2% and will recover within 1% in 50 mSec for a 25% load step change. On outputs #2-5, the peak output voltage excursion will not exceed 1% for a 25% load step change. Output Isolation All outputs are fully isolated. Power Fail Signal Upon AC input voltage removal, the power fail signal drops to logic level ‘0’ at least 5msec before loss of DC output. Upon AC input turn-on, signal remains low until outputs are in regulation. Consult the factory for other options. DC Power Good Signal The signal drops to logic level ‘0’by a ±10% loss of regulation on any output, common with Output #1 (-) sense. Consult the factory for other options. Over Temperature Protection Internal thermal switch turns off power supply if overheating occurs and automatically restarts. Automatic restart when temperature drops below threshold. Safety UL Recognized: UL File Number 14675 (1950 & 1012) CSA Certified: CSA File Number LR9070-154C (C22.2 No. 234-M90, Level 6) TUV License Number:R9576025 (EN60950) (IEC950) Cooling The unit is designed to operate with 30 CFM of airflow. Input Specifications Parameter Conditions Min Typ Max Units Operating Range 47-63Hz 90 264 VAC Inrush Current 120VAC, cold start at 25°C 40 APK 240VAC, cold start at 25°C 80 APK Efficiency Nominal line and full load 75 % Power Factor* 0.99 *Harmonic Correction meets IEC 1000-3-2 (formerly IEC 555-2) The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES product for use in life support devices/systems or in aircraft control applications. |
Similar Part No. - KX500-F5F |
|
Similar Description - KX500-F5F |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |