5 / 17 page LUXEON Rebel PLUS Datasheet DS107 20140122 ©2014 Philips Lumileds Lighting Company. 4 Electrical Characteristics Electrical Characteristics at 350 mA for LUXEON Rebel PLUS, Junction Temperature = 85°C Table 3. Nominal ANSI CCT Forward Voltage V f [1] (V) Typical Temperature Coefficient of Forward Voltage [2] (mV/°C) DV F / DTJ Typical Thermal Resistance Junction to Thermal Pad (°C/W) Ru J-C Min Max 2700K 2.5 3.00 -1.0 to -3.0 9 3000K 2.5 3.00 -1.0 to -3.0 9 3500K 2.5 3.00 -1.0 to -3.0 9 4000K 2.5 3.00 -1.0 to -3.0 9 5000K 2.5 3.00 -1.0 to -3.0 9 Notes for Table 3: 1. Philips Lumileds maintains a tolerance of ±0.06V on forward voltage measurements. 2. Measured between T J = 25°C and TJ = 110°C at If = 350 mA. Absolute Maximum Ratings Table 4. Parameter Maximum Performance DC Forward Current (mA) [2] 1000 Peak Pulsed Forward Current [3] 1000 ESD Sensitivity < 8000V Human Body Model (HBM) Class 3A JESD22-A114-E LED Junction Temperature [1] 150°C Operating Case Temperature at 700 mA -40°C - 135°C Storage Temperature -40°C - 135°C Soldering Temperature JEDEC 020c 260°C Allowable Reflow Cycles 3 Reverse Voltage (V r) LUXEON Rebel PLUS LEDs are not designed to be driven in reverse bias Notes for Table 4: 1. Proper current derating must be observed to maintain junction temperature below the maximum. For additional information on thermal measurement guidelines please refer to Application Brief AB33. 2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple’, with frequencies ≥ 100 Hz and amplitude ≤ 300 mA are acceptable, assuming the average current throughout each cycle does not exceed 1000 mA. 3. Pulsed operation with a peak drive current of 1000 mA is acceptable if the pulse on-time is ≤ 5 ms per cycle and the duty cycle is ≤ 50%. JEDEC Moisture Sensitivity Table 5. Level Floor Life Soak Requirements Standard Time Conditions Time Conditions 1 Unlimited [ 30°C / 85% RH 168 Hrs. + 5 / -0 Hrs. 85°C / 85% RH |
Similar Part No. - LX18-P140-Y |
|
Similar Description - LX18-P140-Y |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |