11 / 14 page MODEL PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48 MAX OUTPUT WATTAGE[W] 66 100 94.5 102 105 108 100.8 100.8 DC OUTPUT 3.3V 20A 5V 20A 9V 10.5A 12V 8.5A 15V 7A 24V 4.5A 36V 2.8A 48V 2.1A SPECIFICATIONS MODEL PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48 INPUT VOLTAGE[V] AC85 - 264 1 f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *4) CURRENT[A] ACIN 100V 0.9typ 1.3typ ACIN 200V 0.5typ 0.7typ FREQUENCY[Hz] 50/60 (47-63) EFFICIENCY[%] ACIN 100V 77typ 82typ 80typ 81typ 83typ 84typ 84typ 84typ ACIN 200V 79typ 84typ 82typ 83typ 86typ 86typ 86typ 86typ POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typ ACIN 200V 0.87typ 0.93typ INRUSH CURRENT[A] ACIN 100V 20typ (Io=100%)(At cold start) ACIN 200V 40typ (Io=100%)(At cold start) LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN) OUTPUT VOLTAGE[V] 3.3 5 9 12 15 24 36 48 CURRENT[A] 20 20 10.5 8.5 7 4.5 2.8 2.1 LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max RIPPLE[mVp-p] 0to+50 C*1 80max 80max 120max 120max 120max 120max 150max 150max -10-0 C*1 140max 140max 160max 160max 160max 160max 200max 200max RIPPLE NOISE[mVp-p] 0to+50 C*1 120max 120max 150max 150max 150max 150max 250max 250max -10-0 C*1 160max 160max 180max 180max 180max 180max 300max 300max TEMPERATURE REGULATION[mV] 0to+50 C 50max 50max 90max 120max 150max 240max 360max 480max -10 to +50 C 60max 60max 120max 150max 180max 290max 450max 600max DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192max START-UP TIME[ms] 350typ(ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0 OUTPUT VOLTAGE SETTING[V] 3.20 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92 PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically OVERVOLTAGE PROTECTION[V] 4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0 OPERATING INDICATION LED (Green) REMOTE SENSING Optional (Only -3R3, -5 Option -K) REMOTE ON/OFF Optional (Required external power source) ISOLATION INPUT-OUTPUT -RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M Wmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M Wmin (At Room Temperature) OUTPUT -RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50M Wmin (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71 C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75 C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR Complies with IEC61000-3-2 OTHERS CASE SIZE/WEIGHT 32 X93X147mm [1.26X3.66X5.79 inches] (without terminal block)(WXHXD) / 440g max (without cover) COOLING METHOD Convection *6 *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and FG. *4 Derating is required. *5 Please contact us about safety approvals for the model with option. *6 Please contact us about class C. * Parallel operation with other model is not possible. * Derating is required when operated with cover. * A sound may occur from power supply at peak loading. PBA100F AC-DC Power Supplies Enclosed type PB A 100 F -5 - O Ordering information 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *5 C :with Coating G :Low leakage current (0.15mA max / ACIN 240V) E :Low leakage current and EMI class A (0.5mA max / ACIN 240V) T :Vertical terminal block J :Connector type (Only -12,-15,-24,-36,-48) R :with Remote ON/OFF N :with Cover (Only 24V UL508 is acquired) N1 :with DIN rail V :Output voltage setting potentiometer external- ly R 123456 PBA/PBW PBA/PBW-12 Recommended EMI/EMC Filter NAC-06-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. Cover is optional |
Similar Part No. - PBA10F-24 |
|
Similar Description - PBA10F-24 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |