Electronic Components Datasheet Search |
|
ICM80000 Datasheet(PDF) 5 Page - List of Unclassifed Manufacturers |
|
ICM80000 Datasheet(HTML) 5 Page - List of Unclassifed Manufacturers |
5 / 8 page 5 24VDC ±10% COMMS PORT RS232/PG PORT USB/PG RS232 POWER CONNECTOR N/C 3 2 COMMON 1 ETHERNET RS485 RS232/PG USB/PG STS ETHERNET (NIC) PORT RS485 ICM8 PORT PIN OUTS TROUBLESHOOTING 1. This module is designed to operate with Red Lion panel meters only. Please make sure a Red Lion product is connected to either one of the two serial ports for the gateway to be active. 2. The Ethernet port is equipped with data LEDs. If they are blinking, the converter is active and the data is available at the port. Please verify the receiving equipment is properly programmed. 3. If for any reason you have trouble operating, connecting, or simply have questions concerning your new ICM8, contact Red Lion’s technical support. For contact information, refer to the back page of this bulletin for phone and fax numbers. EMAIL: techsupport@redlion.net Web Site: http://www.redlion.net CONFIGURING THE ICM8 The ICM8 is configured using Crimson software. Crimson is available as a free download from Red Lion’s website, or it can be ordered on CD. Updates to Crimson for new features and drivers are posted on the website as they become available. Crimson software can configure the ICM8 through the RS232/PG port or USB/PG port. The USB/PG port is connected using a standard USB cable with a Type B connector. The driver needed to use the USB port will be installed with Crimson. The RS232/PG port uses a programming cable made by Red Lion to connect to the DB9 COM port of your computer. If making your own cable, refer to the “ICM8 Port Pin Outs” for wiring information. ETHERNET COMMUNICATIONS Ethernet communications can be established at either 10 BASE-T or 100 BASE-TX. The Crimson manual contains additional information on Ethernet communications. RS232 PORTS The ICM8 has one RS232 port. The port can be used for programming or communications. RS485 PORT The ICM8 has one RS485 port. Note: All Red Lion devices connect A to A and B to B. COMMUNICATING WITH THE ICM8 COMM RECEIVING DEVICE RXD TXD 5 DTE 2 3 DB9 Rx COMM Tx COMM CTS RTS ICM8 RS232/PG PORT RECEIVING DEVICE B (-) A (+) COMM.* * OPTIONAL ICM8 COMMS PORT NC NC A (+) NC COMM B (-) |
Similar Part No. - ICM80000 |
|
Similar Description - ICM80000 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |