11 / 20 page Quad/Octal, 2-Wire Serial 8-Bit DACs with Rail-to-Rail Outputs ______________________________________________________________________________________ 11 START and STOP Conditions When the bus is not in use, both SCL and SDA must be high. A bus master signals the beginning of a transmis- sion with a START condition by transitioning SDA from high to low while SCL is high (Figure 4). When the mas- ter has finished communicating with the slave, it issues a STOP condition by transitioning SDA from low to high while SCL is high. The bus is then free for another transmission. Slave Address The MAX520/MAX521 each have a 7-bit-long slave address (Figure 5). The first four bits (MSBs) of the slave address have been factory programmed and are always 0101. In addition, the MAX521 has the next bit factory programmed to 0. The logic state of the address input pins (AD0, AD1, and AD2 of the MAX520; AD0 and AD1 of the MAX521) determine the least significant bits of the 7-bit slave address. These input pins may be connected to VDD or DGND, or they may be actively driven by TTL or CMOS logic levels. There are four possible slave addresses for the MAX521, and therefore a maximum of four such devices may be on the bus at one time. The MAX520 has eight possible slave addresses. The eighth bit (LSB) in the slave address byte should be low when writing to the MAX520/MAX521. The MAX520/MAX521 monitor the bus continuously, waiting for a START condition followed by its slave address. When a device recognizes its slave address, it is ready to accept data. Command Byte and Output Byte A command byte follows the slave address. Figure 6 shows the format for the command byte. A command byte is usually followed by an output byte unless it is the last byte in the transmission. If it is the last byte, all bits except PD and RST are ignored. If an output byte follows the command byte, A0–A2 of the command byte indicate the digital address of the DAC whose input data latch receives the digital output data. The data is transferred to the DAC’s output latch during the STOP condition following the transmission. This allows all DACs to be updated and the new outputs to appear simultaneously (Figure 7). Setting the PD bit high powers down the MAX520/ MAX521 following a STOP condition (Figure 8a). If a command byte with PD set high is followed by an out- put byte, the addressed DAC’s input latch will be updated and the data will be transferred to the DAC’s output latch following the STOP condition (Figure 8b). If the transmission’s last command byte has PD high, the voltage outputs will not reflect the newly entered data because the DAC will enter power-down mode when the STOP condition is detected. When in power-down, the MAX521’s DAC outputs float, and the MAX520’s unbuffered outputs look like a 16k Ω resistor to AGND. In this mode, the supply current is a maximum of 20µA. A command byte with the PD bit low returns the MAX520/MAX521 to normal operation following a STOP condition, and the voltage outputs reflect the current output-latch contents (Figures 9a and 9b). Because each subsequent command byte overwrites the previ- ous PD bit, only the last command byte of a transmis- sion affects the power-down state. SCL SDA SLAVE ADDRESS BITS AD2, AD1, AND AD0 CORRESPOND TO THE LOGIC STATE OF THE ADDRESS INPUT PINS AD2, AD1, AND AD0. 0 0 1 0 or AD2 10 AD1 AD0 LSB ACK SLAVE ADDRESS Figure 5. Address Byte LSB MSB SDA SCL R2 R1 R0 RST PD A2 A1 A0 ACK R2, R1, R0: RESERVED BITS. SET TO 0. RST: RESET BIT, SET TO 1 TO RESET ALL DAC REGISTERS. PD: POWER-DOWN BIT. SET TO 1 TO PLACE THE DEVICE IN THE 4µA SHUTDOWN MODE. SET TO 0 TO RETURN TO THE NORMAL OPERATIONAL STATE. A2, A1, A0: ADDRESS BITS. DIGITAL ADDRESS FOR DAC0 TO DAC7. DETERMINES WHICH DAC'S INPUT LATCH RECEIVES THE 8 BITS OF DATA IN THE NEXT BYTE. A2 IS IGNORED BY THE MAX520. ACK: ACKNOWLEDGE BIT. THE MAX520/MAX521 PULL SDA LOW DURING THE 9TH CLOCK PULSE. Figure 6. Command Byte SCL SDA START CONDITION STOP CONDITION Figure 4. All communications begin with a START condition and end with a STOP condition, both generated by a bus master. |
Similar Part No. - MAX520BCPE |
|
Similar Description - MAX520BCPE |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |