Electronic Components Datasheet Search |
|
OWA-90E-20 Datasheet(PDF) 2 Page - Mean Well Enterprises Co., Ltd. |
|
OWA-90E-20 Datasheet(HTML) 2 Page - Mean Well Enterprises Co., Ltd. |
2 / 4 page SPECIFICATION OWA-90E series File Name:OWA-90E-SPEC 2015-01-27 MODEL DC VOLTAGE RATED CURRENT RATED POWER OUTPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME Note.4 HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INPUT INRUSH CURRENT (Typ.) LEAKAGE CURRENT WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSION OTHERS NOTE PACKING OVERLOAD OVER VOLTAGE OVER TEMPERATURE 500ms, 80ms at 95% load 115VAC / 230VAC 16ms at full load 115VAC / 230VAC 90 ~ 264VAC 127 ~ 370VDC 47 ~ 63Hz PF>0.98/115VAC, PF>0.96/230VAC at full load 0.95A / 115VAC 0.5A / 230VAC <0.25mA / 240VAC 105 ~ 115% Protection type : Hiccup mode, recovers automatically after fault condition is removed -40 ~ +70 (Refer to "Derating Curve") ℃ 20 ~ 95% RH non-condensing -40 ~ +80 , 10 ~ 95% RH ℃ ±℃ ℃ 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes 292.8K hrs min. MIL-HDBK-217F (25 ) ℃ Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN55014-2, light industry level (surge L- N : 2KV), criteria A 171*63*37.5mm 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. ℃ 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 0.92Kg; 16pcs/15.7Kg/1.01CUFT RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3 ENVIRONMENT PROTECTION Shut down o/p voltage, re-power on to recover SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed Protection type : Shut down o/p voltage, re-power on to recover COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC 15 ~ 17V 17.5 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 40V 41 ~ 46V 46 ~ 54V 54 ~ 60V 59 ~ 66V 89% 90% 90% 90% 90% 91% 91% 91% 91% ±4.0% ±4.0% ±4.0% ±3.0% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% 12V 15V 20V 24V 30V 36V 42V 48V 54V OWA-90E-12 OWA-90E-15 OWA-90E-20 OWA-90E-24 OWA-90E-30 OWA-90E-36 OWA-90E-42 OWA-90E-48 OWA-90E-54 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p 250mVp-p 350mVp-p 7.5A 6A 4.5A 3.75A 3A 2.5A 2.15A 1.88A 1.67A 90W 90W 90W 90W 90W 90W 90.3W 90.24W 90.18W SAFETY & EMC WITHSTAND VOLTAGE ISOLATION RESISTANCE SAFETY STANDARDS EMC IMMUNITY EMC EMISSION EN61558-1,-2-16 listed; EN60335-1 listed(except for OWA-90E-42,48,54); IP67 approved I/P-O/P:3.75KVAC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ℃ Compliance to EN55022 (CISPR22) Class B, EN55014-1, EN61000-3-2,-3 μ 90W Single Output Moistureproof Adaptor |
Similar Part No. - OWA-90E-20 |
|
Similar Description - OWA-90E-20 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |