  1SAZ811201R1002 Datasheet HTML 1Page - List of Unclassifed Manufacturers 1SAZ811201R1002 Datasheet HTML 2Page - List of Unclassifed Manufacturers 1SAZ811201R1002 Datasheet HTML 3Page - List of Unclassifed Manufacturers 1SAZ811201R1002 Datasheet HTML 4Page - List of Unclassifed Manufacturers 1SAZ811201R1002 Datasheet HTML 5Page - List of Unclassifed Manufacturers 1SAZ811201R1002 Datasheet HTML 6Page - List of Unclassifed Manufacturers 1SAZ811201R1002 Datasheet HTML 7Page - List of Unclassifed Manufacturers 1SAZ811201R1002 Datasheet HTML 8Page - List of Unclassifed Manufacturers  
Zoom Inzoom in Zoom Outzoom out
 2 / 8 page
background image
2 - 2CDC106069D0201
Functional description
1
2
3
4
5
6
7
8
9
1 Terminals 1L1, 3L2, 5L3
2 Sealable operating elements
3 Current setting range
Adjustable current setting for overload protection
4 TEST
Status indication
5 RESET
Automatic or manual reset selectable
6 Signaling contacts 97-98
7 Terminals 2T1, 4T2, 6T3
8 Tripping contacts 95-96
9 STOP
Application / internal function
The thermal overload relays are three pole relays with bimetal tripping elements (1 per pole). The motor current flows through
the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal
elements become bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching
position (95-96 / 97-98). The contact 95-96 is used to control the load contactor.
The overload relays have a setting scale in Amperes, which allows the direct adjusting of the relay without any additional
calculation. In compliance with international and national standards, the setting current is the rated current of the motor
and not the tripping current (no tripping at 1.05 x I, tripping at 1.2 x I; I = setting current). The relays are constructed in way
that they protect themselves in the event of an overload. The overload relay has to be protected against short-circuit. The
appropriate short-circuit protective devices are shown in the table.
Operation mode
3~
1~
Contact 95-96
Contact 97-98
Status indication
Comment
Trip state
open
closed
RESET state
closed
open
ON
TEST manual reset mode
open
closed
TEST auto reset mode
open
closed
while TEST is operated
STOP while device is in trip state
open
closed
STOP button has no function
STOP while device is in RESET state
open
open
while STOP button is pressed
Wiring diagram
97
95
98
96
2T1
4T2 6T3
RESET
A
M
TEST
STOP


Similar Part No. - 1SAZ811201R1002

ManufacturerPart #DatasheetDescription
logo
Micro Commercial Compon...
1SA0 MCC-1SA0 Datasheet
86Kb / 3P
   1.0 Amp Schottky Barrier Rectifier 20 to 100 Volts
logo
Shanghai Lunsure Electr...
1SA0 CHENYI-1SA0 Datasheet
54Kb / 3P
   1.0Amp Schottky Barrier Rectifier
logo
Jinan Jingheng (Group) ...
1SA0 JINANJINGHENG-1SA0 Datasheet
65Kb / 2P
   SCHOTTKY BARRIER RECTIFIER
logo
Shanghai Shunye Electro...
1SA0 SY-1SA0 Datasheet
260Kb / 2P
   SCHOTTKY BARRIER RECTIFIER
1SA0 SHUNYE-1SA0 Datasheet
259Kb / 2P
   SCHOTTKY BARRIER RECTIFIER
More results

Similar Description - 1SAZ811201R1002

ManufacturerPart #DatasheetDescription
logo
Schneider Electric
LA7D3064 SCHNEIDER-LA7D3064 Datasheet
131Kb / 1P
   TeSys LRD thermal overload relay, terminal block adaptor
Aug 10, 2019
logo
STMicroelectronics
L78 STMICROELECTRONICS-L78 Datasheet
2Mb / 54P
   Thermal overload protection
November 2016 Rev 34
logo
Schneider Electric
LR9D01 SCHNEIDER-LR9D01 Datasheet
122Kb / 3P
   TeSys LRD - electronic thermal overload relay - 3P - 0.1...0.5 A
LR9D01 SCHNEIDER-LR9D01_V01 Datasheet
136Kb / 3P
   TeSys LRD - electronic thermal overload relay - 3P - 0.1...0.5 A
May 30, 2022
DPER08 SCHNEIDER-DPER08 Datasheet
133Kb / 3P
   Easy TeSys DPER thermal overload relay, 2.5?? A, class 10
logo
M.S. Kennedy Corporatio...
MSK5212 MSK-MSK5212 Datasheet
151Kb / 6P
   Internal Thermal Overload Protection
MSK5214 MSK-MSK5214 Datasheet
151Kb / 6P
   Internal Thermal Overload Protection
logo
Schneider Electric
LR9D32 SCHNEIDER-LR9D32 Datasheet
120Kb / 3P
   TeSys LRD - electronic thermal overload relay - 3P - 6.4...32 A
logo
Inchange Semiconductor ...
LM7805 ISC-LM7805 Datasheet
239Kb / 2P
   Internal thermal overload protection
logo
M.S. Kennedy Corporatio...
MSK5211 MSK-MSK5211 Datasheet
151Kb / 6P
   Internal Thermal Overload Protection
More results


Html Pages

1 2 3 4 5 6 7 8


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.NET
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com