Electronic Components Datasheet Search |
|
MHI124D-05DI5.7 Datasheet(PDF) 2 Page - MicroPower Direct, LLC |
|
MHI124D-05DI5.7 Datasheet(HTML) 2 Page - MicroPower Direct, LLC |
2 / 3 page www.micropowerdirect.com MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Model Selection Guide Model Number Input Output Efficiency (%, Typ) Load Regulation (%, Max) Capacitive Load (µF, Max) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min) Nominal Range Full-Load No-Load MHI105S-03DI5.7 5 4.5 - 5.5 286 35 3.3 303 0.0 70 ±20.0 1,000 500 MHI105S-05DI5.7 5 4.5 - 5.5 286 35 5.0 200 0.0 70 ±15.0 470 500 MHI105S-09DI5.7 5 4.5 - 5.5 266 35 9.0 111 0.0 75 ±10.0 470 500 MHI105S-12DI5.7 5 4.5 - 5.5 261 35 12.0 84 0.0 77 ±10.0 220 500 MHI105S-15DI5.7 5 4.5 - 5.5 254 35 15.0 66 0.0 78 ±10.0 220 500 MHI105D-05DI5.7 5 4.5 - 5.5 282 35 ±5.0 ±100 ±0.0 71 ±15.0 220 500 MHI105D-09DI5.7 5 4.5 - 5.5 269 35 ±9.0 ±56 ±0.0 75 ±10.0 220 500 MHI105D-12DI5.7 5 4.5 - 5.5 262 35 ±12.0 ±42 ±0.0 77 ±10.0 100 500 MHI105D-15DI5.7 5 4.5 - 5.5 254 35 ±15.0 ±33 ±0.0 78 ±10.0 100 500 MHI105D-1509DI5.7 5 4.5 - 5.5 260 35 +15.0 +33 ±0.0 76 ±10.0 100 500 -9.0 -55 220 500 MHI112S-03DI5.7 12 10.8 - 13.2 117 17 3.3 303 0.0 71 ±20.0 1,000 250 MHI112S-05DI5.7 12 10.8 - 13.2 117 17 5.0 200 0.0 71 ±15.0 470 250 MHI112S-09DI5.7 12 10.8 - 13.2 110 17 9.0 111 0.0 76 ±10.0 470 250 MHI112S-12DI5.7 12 10.8 - 13.2 108 17 12.0 84 0.0 78 ±10.0 220 250 MHI112S-15DI5.7 12 10.8 - 13.2 104 17 15.0 66 0.0 79 ±10.0 220 250 MHI112D-05DI5.7 12 10.8 - 13.2 116 17 ±5.0 ±100 ±0.0 72 ±15.0 220 250 MHI112D-09DI5.7 12 10.8 - 13.2 111 17 ±9.0 ±56 ±0.0 75 ±10.0 220 250 MHI112D-12DI5.7 12 10.8 - 13.2 108 17 ±12.0 ±42 ±0.0 78 ±10.0 100 250 MHI112D-15DI5.7 12 10.8 - 13.2 104 17 ±15.0 ±33 ±0.0 79 ±10.0 100 250 MHI112D-1509DI5.7 12 10.8 - 13.2 107 17 +15.0 +33 ±0.0 77 ±10.0 100 250 -9.0 -55 220 250 MHI115S-03DI5.7 15 13.5 - 16.5 95 16 3.3 303 0.0 70 ±20.0 1,000 200 MHI115S-05DI5.7 15 13.5 - 16.5 95 16 5.0 200 0.0 70 ±15.0 470 200 MHI115S-09DI5.7 15 13.5 - 16.5 89 16 9.0 111 0.0 75 ±10.0 470 200 MHI115S-12DI5.7 15 13.5 - 16.5 90 16 12.0 84 0.0 75 ±10.0 220 200 MHI115S-15DI5.7 15 13.5 - 16.5 84 16 15.0 66 0.0 79 ±10.0 220 200 MHI115D-05DI5.7 15 13.5 - 16.5 94 16 ±5.0 ±100 ±0.0 71 ±15.0 220 200 MHI115D-09DI5.7 15 13.5 - 16.5 90 16 ±9.0 ±56 ±0.0 75 ±10.0 220 200 MHI115D-12DI5.7 15 13.5 - 16.5 86 16 ±12.0 ±42 ±0.0 78 ±10.0 100 200 MHI115D-15DI5.7 15 13.5 - 16.5 84 16 ±15.0 ±33 ±0.0 79 ±10.0 100 200 MHI115D-1509DI5.7 15 13.5 - 16.5 87 16 +15.0 +33 ±0.0 76 ±10.0 100 200 -9.0 -55 220 200 MHI124S-03DI5.7 24 21.6 - 26.4 60 12 3.3 303 0.0 70 ±20.0 1,000 150 MHI124S-05DI5.7 24 21.6 - 26.4 60 12 5.0 200 0.0 70 ±15.0 470 150 MHI124S-09DI5.7 24 21.6 - 26.4 56 12 9.0 111 0.0 75 ±10.0 470 150 MHI124S-12DI5.7 24 21.6 - 26.4 53 12 12.0 84 0.0 78 ±10.0 220 150 MHI124S-15DI5.7 24 21.6 - 26.4 52 12 15.0 66 0.0 80 ±10.0 220 150 MHI124D-05DI5.7 24 21.6 - 26.4 59 12 ±5.0 ±100 ±0.0 71 ±15.0 220 150 MHI124D-09DI5.7 24 21.6 - 26.4 56 12 ±9.0 ±56 ±0.0 75 ±10.0 220 150 MHI124D-12DI5.7 24 21.6 - 26.4 55 12 ±12.0 ±42 ±0.0 77 ±10.0 100 150 MHI124D-15DI5.7 24 21.6 - 26.4 53 12 ±15.0 ±33 ±0.0 78 ±10.0 100 150 MHI124D-1509DI5.7 24 21.6 - 26.4 55 12 +15.0 +33 ±0.0 75 ±10.0 100 150 -9.0 -55 220 150 Notes: 1. The specified maximum capacitive load is for each output. 2. Load regulation is measured over a range of 20% IOUT to 100% IOUT. 3. When measuring output ripple & noise, it is recommended that an external capacitor (1 µF typ.) be placed from the +VOUT to the -VOUT pins for single output units and from each output to common for dual output models. 4. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is sup- plied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 2.2 µF is recom- mended; for 12V & 15V input units, a 1.0 µF; and for 24V units a 0.47 µF. 5. Operation at no-load will not damage the unit, but they may not meet all specifica- tions. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection tables for the correct rating. Derating Curve |
Similar Part No. - MHI124D-05DI5.7 |
|
Similar Description - MHI124D-05DI5.7 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |