CY7C460A/CY7C462A
CY7C464A/CY7C466A
Document #: 38-06011 Rev. *A
Page 2 of 15
Maximum Ratings [1]
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ..................................–65
°C to +150°C
Ambient Temperature with
Power Applied.............................................–55
°C to +125°C
Supply Voltage to Ground Potential ............... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State ............................................... –0.5V to +7.0V
DC Input Voltage............................................ –0.5V to +7.0V
Power Dissipation ..........................................................1.0W
Output Current, into Outputs (LOW)............................ 20 mA
Static Discharge Voltage............................................ >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current ..................................................... >200 mA
Selection Guide
7C460A-10
7C462A-10
7C464A-10
7C466A-10
7C460A-15
7C462A-15
7C464A-15
7C466A-15
7C460A-25
7C462A-25
7C464A-25
7C466A-25
Frequency (MHz)
50
40
28.5
Maximum Access Time (ns)
10
15
25
Operating Range
Range
Ambient
Temperature
VCC
Commercial
0
°C to + 70°C
5V
± 10%
Industrial
–40
°C to +85°C
5V
± 10%
Military[2]
–55
°C to +125°C
5V
± 10%
Electrical Characteristics Over the Operating Range[3]
Parameter
Description
Test Conditions
7C460A/462A/464A/466A
(-10,-15,-25)
Unit
Min.
Max.
VOH
Output HIGH Voltage
VCC = Min., IOH = −2.0 mA
2.4
V
VOL
Output LOW Voltage
VCC = Min., IOL = 8.0 mA
0.4
V
VIH
Input HIGH Voltage
2.2
VCC
V
VIL
Input LOW Voltage
−0.5
0.8
V
IIX
Input Leakage Current
GND < VI < VCC
–10
+10
µA
IOZ
Output Leakage Current
R > VIH, GND < VO < VCC
–10
+10
µA
ICC
Operating Current
VCC = Max.,
IOUT = 0 mA, Freq. = 20 MHz
60
mA
ISB
Standby Current
All Inputs = VIH min.
8
mA
Capacitance[5]
Parameter
Description
Test Conditions
Max.
Unit
CIN
Input Capacitance
TA = 25°C, f = 1 MHz,
VCC = 4.5V
10
pF
COUT
Output Capacitance
12
pF
Notes:
1.
The Voltage on any input or I/O pin cannot exceed the power pin during power-up.
2.
TA is the “instant on” case temperature.
3.
See the last page of this specification for Group A subgroup testing information.
4.
For test purposes, not more than one output at a time should be shorted. Short circuit test duration should not exceed 1 second.
5.
Tested initially and after any design or process changes that may affect these parameters.