CY62128V Family
2
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied ............................................. –55°C to +125°C
Supply Voltage to Ground Potential
(Pin 28 to Pin 14) ........................................... –0.5V to +4.6V
DC Voltage Applied to Outputs
in High Z State[1] ....................................–0.5V to VCC + 0.5V
DC Input Voltage[1].................................–0.5V to VCC + 0.5V
Output Current into Outputs (LOW) ............................. 20 mA
Static Discharge Voltage .......................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current .................................................... >200 mA
Operating Range
Range
Ambient Temperature
VCC
Commercial
0°C to +70°C
1.6V to 3.6V
Industrial
–40°C to +85°C
1.6V to 3.6V
Product Portfolio
VCC Range
Power Dissipation (Commercial)
Operating (ICC)
Standby (ISB2)
Product
Min.
Typ.[2]
Max.
Speed
Typ.[2]
Maximum
Typ.[2]
Maximum
CY62128V
2.7V
3.0V
3.6V
55, 70 ns
20 mA
40 mA
0.4
µA
100
µA (XL = 10 µA)
CY62128V25
2.3V
2.5V
2.7V
100 ns
15 mA
20 mA
0.3
µA
50
µA (LL = 12 µA)
CY62128V18
1.6V
1.8V
2.0V
200 ns
10 mA
15 mA
0.3
µA
30
µA (LL = 10 µA)
Electrical Characteristics Over the Operating Range
CY62128V-55/70
Parameter
Description
Test Conditions
Min.
Typ.[2]
Max.
Unit
VOH
Output HIGH Voltage
VCC = Min., IOH = –1.0 mA
2.4
V
VOL
Output LOW Voltage
VCC = Min., IOL = 2.1 mA
0.4
V
VIH
Input HIGH Voltage
2
VCC
+0.5V
V
VIL
Input LOW Voltage
–0.5
0.8
V
IIX
Input Load Current
GND < VI < VCC
–1
±1
+1
µA
IOZ
Output Leakage Current
GND < VO < VCC, Output Disabled
–1
±1
+1
µA
ICC
VCC Operating Supply
Current
VCC = Max.,
IOUT = 0 mA,
f = fMAX = 1/tRC
Com’l,
70 ns
L
20
40
mA
LL, XL
20
40
Ind’l,
55 ns
LL
23
50
Ind’l,
70 ns
L
20
40
LL
20
40
ISB1
Automatic CE
Power-Down Current—
TTL Inputs
Max. VCC, CE > VIH,
VIN > VIH or
VIN < VIL, f = fMAX
Com’l,
70 ns
L
15
300
µA
LL, XL
15
300
Coml,
55 ns
LL
17
350
Ind’l
L
15
300
LL
15
300
Notes:
1.
VIL (min.) = –2.0V for pulse durations of less than 20 ns.
2.