Electronic Components Datasheet Search |
|
AH05 Datasheet(PDF) 9 Page - XP Power Limited |
|
AH05 Datasheet(HTML) 9 Page - XP Power Limited |
9 / 10 page 4389U04 PAGE 9 WWW.XPPOWER.COM Typical HV Output vs. Control Voltage 0 50 100 150 200 250 300 0 10 20 30 40 50 60 70 80 90 100 % Control Voltage NOTE: Vin held at maximum Full Load Output No Load Output (A) No Load Output (AH) Safe Operating Limit TYPICAL INPUT vs. OUTPUT VOLTAGE 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 % INPUT VOLTAGE NOTE: Control Pin tied to Vin Pin loaded unloaded (A) unloaded (AH) A SERIES APPLICATION NOTES Typical HV Output vs. Control Voltage Typical Input vs. Output Voltage Output Voltage is load dependent. Under light or no-load conditions, reduce the Input Voltage so maximum rated Output Voltage is not exceeded. |
Similar Part No. - AH05 |
|
Similar Description - AH05 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |