Electronic Components Datasheet Search |
|
D1U54P-W-650-12-HBXC Datasheet(PDF) 2 Page - Murata Power Solutions Inc. |
|
D1U54P-W-650-12-HBXC Datasheet(HTML) 2 Page - Murata Power Solutions Inc. |
2 / 9 page D1U54P-W-650-12-HBxC Series 54mm 1U Front End AC-DC Power Supply Converter D1U54P-W-650-12-HBxC.A02 Page 2 of 9 www.murata-ps.com/support OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Startup Time AC ramp up Note: Following a “turn off” of the 12V Main output (for any reason whatsoever) the output shall not be allowed to “turn on” again for 1sec (even if all necessary operating conditions are met). 3 s Transient Response Main 12V, 50% load step, 1A/μs di/dt ±5 500 % µs 12VSB, 50% load step, 1A/μs di/dt Current sharing accuracy (Main 12V output) >10% load; (* percentage of full load) ±5* % Hot Swap Transients ±5 % Holdup Time (Total Effective Hold Up - See Timing Waveforms) Full AC Input Source Range; full load 12 ms ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Storage Temperature Range -40 70 °C Operating Temperature Range 90V-264Vac, 650W -5 50 Operating Humidity Noncondensing; +45°C 5 90 % Storage Humidity 5 95 Altitude (without derating at 40°C) 3000 m Shock 30G non-operating Operational Vibration Sine sweep; 5-200Hz, 2G; random vibration, 5-500Hz, 1.11G MTBF(Target) Per Telcordia SR-332 M1C1 @40°C 576K hrs Safety Approvals CAN/CSA C22.2 No 60950-1-07, Am.1:2011, Am 2:2014 ANSI/UL 60950-1-2014 IEC60950-1:2005 (2nd Ed.), Am 1:2009 + Am 2:2013 EN 60950-1:2006+A11:2009 +A1:2010 +A12:2011 +A2:2013 BSMI CNS14336-1 (099/09/30); CNS13438 ((095/06/01) CCC GB4943.1-2011; GB9254-1-2008; GB17625, 1-2012 Input Fuse Power Supply has internal 12.5A/250V fast blow fuse on the AC line input Weight 1.63 lbs (0.741 kg) AIRFLOW; PRESSURE VS. FLOW (PQ) CURVES D1U54P-W-650-12-HB3C & D1U54P-W-650-12-HB4C Orignal curve in Excel spreadsheet at following location: M1845_airflow_meas_01-12-2015.xlsx Notes: 1. The above curves represent performance based upon the use of a 20mm thickness fan. 2. Curves recorded at room ambient (circa 25°C). 3. Curves generated with intermal fan running at 100% duty cycle 0 50 100 150 200 250 0 2 4 6 8 10 PSU airflow (CFM) D1U54-W-650-12-HBxC P & Q CURVE Airflow Front to Back Airflow Back to Front |
Similar Part No. - D1U54P-W-650-12-HBXC |
|
Similar Description - D1U54P-W-650-12-HBXC |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |