1 / 2 page Specification 10 Watts • 2:1 Input Range • Industry Standard Package • 1500 VDC Isolation • Continuous Short Circuit Protection • 40 °C to +100 °C Operating Temperature • Single & Dual Outputs • 3 Year Warranty JCH Series Input Input Voltage Range • 12 V (9-18 VDC) 24 V (18-36 VDC) 48 V (36-72 VDC) Input Current • See table Input Reflected • 35 mA rms through 12 µH inductor Ripple Current Input Filter • Pi network Input Surge • 12 V models 25 VDC for 100 ms 24 V models 50 VDC for 100 ms 48 V models 100 VDC for 100 ms Output Output Voltage • See table Voltage Balance • ±1% (±2% for dual output 3.3 V models) Minimum Load • No minimum load required Line Regulation • ±0.5% Load Regulation • ±0.5% single outputs, ±1.0 dual outputs Setpoint Accuracy • ±1.0% Ripple & Noise • 100 mV pk-pk for 3.3 V to 15 V models, 150 mV pk-pk for 24 V models, 20 MHz bandwidth Transient Response • 3% max deviation, recovery to within 1% in 250 µs for a 25% load change Temperature • 0.02%/°C Coefficient Overload Protection • 140% of full load Short Circuit Protection • Trip & restart (hiccup mode) with auto recovery Maximum Capacitive • See table Load Start Up Delay • <20 ms xppower.com General Efficiency • See table Isolation Voltage • 1500 VDC Input to Output 1000 VDC Input to Case 1000 VDC Output to Case Isolation Capacitance • 500 pF typical input to output Isolation Resistance • 109 Ω Switching Frequency • 200 kHz typical Power Density • 12.5 W/in3 MTBF • >1.1 MHrs to MIL-STD-217F at 25 °C, GB Environmental Operating Temperature • -40 °C to +100 °C, derate from 100% load at +85 °C to 0% load at +100 °C Case Temperature • +100 °C max Storage Temperature • -40 °C to +125 °C Cooling • Convection-cooled Operating Humidity • Up to 95% RH, non-condensing EMC Emissions • EN55022 Class A conducted & radiated with external components, see application note ESD Immunity • EN61000-4-2, 8 kV air discharge Perf Criteria A Radiated Immunity • EN61000-4-3, 3 V/m, Perf Criteria A |
Similar Part No. - JCH1012D03 |
|
Similar Description - JCH1012D03 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |