2 / 9 page
CY7C128A
2
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65
°C to +150°C
Ambient Temperature with
Power Applied............................................. –55
°C to +125°C
Supply Voltage to Ground Potential
(Pin 28 to Pin 14) ........................................... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State ............................................... –0.5V to +7.0V
DC Input Voltage............................................ –3.0V to +7.0V
Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage .......................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current .................................................... >200 mA
Operating Range
Range
Ambient
Temperature
VCC
Commercial
0
°C to +70°C
5V
± 10%
Military[1]
–55
°C to +125°C
5V
± 10%
Electrical Characteristics Over the Operating Range[2]
7C128A–15
7C128A–20
7C128A–25 7C128A–35,45
Parameter
Description
Test Conditions
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Unit
VOH
Output HIGH
Voltage
VCC = Min.,
IOH = –4.0 mA
2.4
2.4
2.4
2.4
V
VOL
Output LOW
Voltage
VCC = Min., IOL = 8.0 mA
0.4
0.4
0.4
0.4
V
VIH
Input HIGH
Voltage
2.2
VCC
2.2
VCC
2.2
VCC
2.2
VCC
V
VIL
Input LOW
Voltage[3]
–0.5
0.8
–0.5
0.8
–0.5
0.8
–0.5
0.8
V
IIX
Input Load
Current
GND < VI < VCC
–10
+10
–10
+10
–10
+10
–10
+10
µA
IOZ
Output Leakage
Current
GND < VI < VCC
Output Disabled
–10
+10
–10
+10
–10
+10
–10
+10
µA
IOS
Output Short
Circuit Current[4]
VCC = Max.,
VOUT = GND
–300
–300
–300
–300
mA
ICC
VCC Operating
Supply Current
VCC = Max.
IOUT = 0 mA
Com’l
120
100
100
100
mA
Mil
125
125
100
ISB1
Automatic CE
Power-Down
Current
Max. VCC,
CE > VIH,
Min. Duty Cycle
= 100%
Com’l
40
40
20
20
mA
Mil
40
40
20
ISB2
Automatic CE
Power-Down
Current
Max. VCC,
CE1 >VCC–0.3V,
VIN > VCC–0.3V
or VIN < 0.3V
Com’l
40
20
20
20
mA
Mil
20
20
20
Capacitance[5]
Parameter
Description
Test Conditions
Max.
Unit
CIN
Input Capacitance
TA = 25°C, f = 1 MHz,
VCC = 5.0V
10
pF
COUT
Output Capacitance
10
pF
Notes:
1.
TA is the “instant on” case temperature.
2.
See the last page of this specification for Group A subgroup testing information.
3.
VIL (min.) = –3.0V for pulse durations less than 30 ns.
4.
Not more than 1 output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
5.
Tested initially and after any design or process changes that may affect these parameters.