Electronic Components Datasheet Search |
|
H40A-4000-AZC-15V Datasheet(PDF) 1 Page - List of Unclassifed Manufacturers |
|
H40A-4000-AZC-15V Datasheet(HTML) 1 Page - List of Unclassifed Manufacturers |
1 / 2 page Tel: 805-968-0782 /800-350-2727 | Fax: 805-968-3154 / 800-960-2726 | 7230 Hollister Ave., Goleta, CA 93117-2807 | www.beisensors.com Specification No. 02045-001 Rev.08-11 H40 Shock Proof Optical Encoder The H40 is an ultra heavy duty encoder whose internal structure is totally isolated from severe shock and shaft loading conditions. The optics and electronics are supported in shock absorbing material within the heavy cast outer housing. The encoder shaft is flexibly coupled to the high load capacity bearings and shaft assembly, which is carried in the outer housing. The entire bearing assembly is field-removable to permit proper shaft support while pressing pul- leys, gears, etc. onto the shaft. An Underwriters Laboratories listed version of this model is available. Mechanical Specifications Shaft Diameter: 5/8” nominal Flats On Shaft: Two flats, 0.75” long X 0.30” deep at 90º Shaft Loading/Bearing Life: Refer to figure 1, back page Shaft Runout: 0.001” T.I.R. at mid-point of shaft Starting Torque at 25° C: 10.0 in-oz (max) Bearings: Class 52100 SAE high carbon steel, stainless steel option Shaft Material: 1070 carbon steel, 303 and 316 stainless steel optional Enclosure: Die cast aluminum, hard anodized with dichro- mate sealed finish (optional). Shaft seals and sealed bearings are standard to achieve environmental ratings. Maximum RPM: 10,000 RPM (see frequency response, below) Coupling Windup: The H40 uses an internal coupling. Windup error (degrees) = a X 7.5 X 10-4 rad/sec2 where a = angular acceleration in rad/sec2 Weight: Approx 9 lbs Electrical Specifications Output Format: 2 channels in quadrature, 1/2 cycle index gated with negative B channel Cycles per Shaft Turn: 1 to 72,000 (see Table 3). For resolutions above 3,600 see interpolation options in the BEI 2008 Spec Guide on pages 36 and 37. Supply Voltage: 5 to 28 VDC available Current Requirements: 100 mA typical + output load, 250 mA (max) Voltage/Output: (see note 5) 15V/V: Line Driver, 5–15 VDC in, Vout = Vin 28V/V: Line Driver, 5–28 VDC in, Vout = Vin 28V/5: Line Driver, 5–28 VDC in, Vout = 5 VDC 28V/OC: Open Collector, 5 – 28 VDC in, OCout Protection Level: Reverse, overvoltage and output short circuit (see note 5) Frequency Response: 100 KHz, up to 1 MHz with interpolation option (see note 5) Output Terminations: see Table 2, back page Termination Type: Compression type, UL recognized. Accepts AWG 14 to 22, stranded wire, strip 1/4” Note: Consult factory for other electrical options Environmental Specifications Enclosure Rating: NEMA 4 X & 6 (IP66), outdoor Non-Hazardous locations, NEMA 4 X & 13 (IP66), indoor Non-Hazardous locations Hazardous Area Rating: The optional Underwriters Laboratories listed version is for use in hazardous locations; NEMA Enclosure 7. Class 1, Group D, Division 1, NEC Class 2 circuits only Temperature: Operating, 0º to 70º C; extended temperature testing available (see note 6); 80º C max for UL and CEN approved units; storage; -25º to 90º C Shock: 200 g’s at 11msec Vibration: 5 to 2000 Hz @ 20 g’s Humidity: 100% RH H40 Shock Proof Ordering Options for assistance call 800-350-2727 Use this diagram, working from left to right to construct your model number (example: H40A-2000-ABZC-28V/V-SC-UL). All notes and tables referred to can be found on the back of this page. NOTES & TABLES: All notes and tables referred to in the text can be found on the back page. The H40 Shock Proof Encoder is available with the following certifications: C Canadian Standards Class I, Group D, Division 1 U.S. Standards Class I, Group D, Division 1 EN 55011 and EN 61000-6-2 TYPE: H = Heavy Duty; 40 = 4.00” Square NO. OF CHANNELS: A = Single Channel AB = Dual Quad. Ch. ABZ = Dual with Index AZ = Single with Index See note 1 VOLTAgE/OuTPuT: 15V/V = 5–15 Vin/out 28V/V = 5–28Vin/out 28V/5 = 5–28Vin/5Vout 28V/OC = 5–28Vin/ OCout See note 3 HOuSINg CONFIguRATION: A = Base Mounted Feet B = No Mounting Feet COMPLEMENTS: C = Complementary Outputs, Blank = None See note 2 OuTPuT TERMINATION: SC = Side Conduit EC = End Conduit; Conduit uses 1/2–14 NPSF (dryseal) straight pipe threads; EM16 = MS3102R16S-1P EM18 = MS3102R18-1P, See Table 1, back page CERTIFICATION: UL = UL Explosion Proof rating, only available with SC termination SPECIAL FEATuRES: S= Special features specified on purchase order (consult factory) See note 4 CYCLES PER TuRN: Enter Cycles See Table 3 H40 |
Similar Part No. - H40A-4000-AZC-15V |
|
Similar Description - H40A-4000-AZC-15V |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |