5 / 8 page 5 Overview The DIP Switches and the Default Serial Terminal set the DLCD serial communication operating mode to either DH-485 mode or MODBUS mode. DH-485 mode allows the DLCD to be connected to a DH-485 network. MODBUS mode allows programming of the DLCD using RLCPro. DH-485 Mode Integer File Each DLCD is assigned a unique Integer File in the PLC that the DLCD uses to transfer data. Switch A (SWA) sets the target Integer file in the range N7..N70. Note N8 and N9 are invalid Integer File numbers and therefore cannot be used. Table 16 - Integer File settings using DIP Switch A DLCD Address Each device on a DH-485 network must have a unique address. Switch B (SWB) allows the DLCD address to be set in the range 0..31. Table 17 - Selections for DLCD Address using DIP Switch B PLC Address The DLCD transfers data with a target PLC. Switch B (SWB) allows the address of the target PLC on the DH-485 network to be set in the range 0..7. Table 18 - Selections for PLC Address using DIP Switch B Example 1 This example shows the DIP Switch settings for a DLCD operating in DH- 485 mode with the following configuration. PLC Address : 1 DLCD Address : 8 Integer File : 10 (N10) Communication Settings The DLCD has a fixed baud rate of 19200 when used in DH-485 mode. 2.0 Setting the DIP Switches INTEGER FILE SWITCH POSITION COMMENT 1 2 3 4 5 6 N7 DN DN DN DN DN DN Valid File Number N8 DN DN DN DN DN UP Invalid File Number N9 DN DN DN DN UP DN Invalid File Number N10 DN DN DN DN UP UP Valid File Number N11 DN DN DN UP DN DN Valid File Number .. Valid File Number N70 UP UP UP UP UP UP Valid File Number DLCD Address Switch Position 1 2 3 4 5 0 DN DN DN DN DN 1 DN DN DN DN UP 2 DN DN DN UP DN 3 DN DN DN UP UP .. 31 UP UP UP UP UP PLC ADDRESS SWITCH POSITION 6 7 8 0 DN DN DN 1 DN DN UP 2 DN UP DN .. 7 UP UP UP 1 2 3 4 5 6 1 2 3 4 5 6 7 8 UP UP UP UP DN DN DN DN DN DN DN DN DN DN MODBUS Mode In MODBUS mode, the DLCD responds to MODBUS RTU frames and therefore allows programming using RLCPro (refer to DLC Bulletin for detailed information on using RLCPro with the DLCD). To configure the DLCD for MODBUS without changing the DIP switches, use the Default Serial Setting Terminal. DN DN DN DN DN DN DN DN DN DN DN DN DN DN 8 7 6 5 4 3 2 1 6 5 4 3 2 1 none 8 Parity: Data Bits: 9600 Baud Rate: 247 Address: RTU Protocol: Serial Communication Defaults: DEFAULT SERIAL SETTING CONNECTIONS If using software selectable serial settings and the serial settings are unknown or forgotten, they can be temporarily reset to the defaults by connecting the “Default Serial Setting” terminal 7 to “Output Common” terminal 4 with a jumper. Alternatively, set all DIP switches Down as shown in Example 2. The DLCD leaves the factory in this state, and is therefore ready to be programmed using RLCPro. Example 2 This example shows the DIP Switch settings for a DLCD operating in MODBUS mode with the default serial settings. |
Similar Part No. - DLCD0001 |
|
Similar Description - DLCD0001 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |