  TMC262_17 Datasheet HTML 1Page - TRINAMIC Motion Control GmbH & Co. KG. TMC262_17 Datasheet HTML 2Page - TRINAMIC Motion Control GmbH & Co. KG. TMC262_17 Datasheet HTML 3Page - TRINAMIC Motion Control GmbH & Co. KG. TMC262_17 Datasheet HTML 4Page - TRINAMIC Motion Control GmbH & Co. KG. TMC262_17 Datasheet HTML 5Page - TRINAMIC Motion Control GmbH & Co. KG. TMC262_17 Datasheet HTML 6Page - TRINAMIC Motion Control GmbH & Co. KG. TMC262_17 Datasheet HTML 7Page - TRINAMIC Motion Control GmbH & Co. KG. TMC262_17 Datasheet HTML 8Page - TRINAMIC Motion Control GmbH & Co. KG. TMC262_17 Datasheet HTML 9Page - TRINAMIC Motion Control GmbH & Co. KG. Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 58 page
background image
TMC262 DATASHEET (Rev. 2.14 / 2016-JUL-14)
5
www.trinamic.com
In addition to these performance enhancements, TRINAMIC motor drivers also offer safeguards to
detect and protect against shorted outputs, open-circuit output, overtemperature, and undervoltage
conditions for enhancing safety and recovery from equipment malfunctions.
1.2 Control Interfaces
There are two control interfaces from the motion controller to the motor driver: the SPI serial
interface and the STEP/DIR interface. The SPI interface is used to write control information to the chip
and read back status information. This interface must be used to initialize parameters and modes
necessary to enable driving the motor. This interface may also be used for directly setting the currents
flowing through the motor coils, as an alternative to stepping the motor using the STEP and DIR
signals, so the motor can be controlled through the SPI interface alone.
The STEP/DIR interface is a traditional motor control interface available for adapting existing designs
to use TRINAMIC motor drivers. Using only the SPI interface requires slightly more CPU overhead to
look up the sine tables and send out new current values for the coils.
1.2.1 SPI Interface
The SPI interface is a bit-serial interface synchronous to a bus clock. For every bit sent from the bus
master to the bus slave, another bit is sent simultaneously from the slave to the master.
Communication between an SPI master and the TMC262 slave always consists of sending one 20-bit
command word and receiving one 20-bit status word.
The SPI command rate typically corresponds to the microstep rate at low velocities. At high velocities,
the rate may be limited by CPU bandwidth to 10-100 thousand commands per second, so the
application may need to change to fullstep resolution.
1.2.2 STEP/DIR Interface
The STEP/DIR interface is enabled by default. Active edges on the STEP input can be rising edges or
both rising and falling edges, as controlled by another mode bit (DEDGE). Using both edges cuts the
toggle rate of the STEP signal in half, which is useful for communication over slow interfaces such as
optically isolated interfaces.
On each active edge, the state sampled from the DIR input determines whether to step forward or
back. Each step can be a fullstep or a microstep, in which there are 2, 4, 8, 16, 32, 64, 128, or 256
microsteps per fullstep. During microstepping, a low state on DIR increases the microstep counter and
a high decreases the counter by an amount controlled by the microstep resolution. An internal table
translates the counter value into the sine and cosine values which control the motor current for
microstepping.
1.3 Mechanical Load Sensing
The TMC262 provides stallGuard2 high-resolution load measurement for determining the mechanical
load on the motor by measuring the back EMF. In addition to detecting when a motor stalls, this
feature can be used for homing to a mechanical stop without a limit switch or proximity detector. The
coolStep power-saving mechanism uses stallGuard2 to reduce the motor current to the minimum
motor current required to meet the actual load placed on the motor.
1.4 Current Control
Current into the motor coils is controlled using a cycle-by-cycle chopper mode. Two chopper modes
are available: a traditional constant off-time mode and the new spreadCycle mode. spreadCycle mode
offers smoother operation and greater power efficiency over a wide range of speed and load.


Similar Part No. - TMC262_17

ManufacturerPart #DatasheetDescription
logo
TRINAMIC Motion Control...
TMC262 TRINAMIC-TMC262_15 Datasheet
1Mb / 58P
   POWER DRIVER FOR STEPPER MOTORS
More results

Similar Description - TMC262_17

ManufacturerPart #DatasheetDescription
logo
TRINAMIC Motion Control...
TMC5130A-TA TRINAMIC-TMC5130A-TA_17 Datasheet
2Mb / 128P
   POWER DRIVER FOR STEPPER MOTORS
TMC261-PA TRINAMIC-TMC261-PA Datasheet
1Mb / 53P
   POWER DRIVER FOR STEPPER MOTORS
TMC2041-LA TRINAMIC-TMC2041-LA Datasheet
2Mb / 66P
   POWER DRIVER FOR STEPPER MOTORS
TMC262 TRINAMIC-TMC262 Datasheet
1Mb / 58P
   POWER DRIVER FOR STEPPER MOTORS
TMC2130-LA TRINAMIC-TMC2130-LA Datasheet
2Mb / 103P
   POWER DRIVER FOR STEPPER MOTORS
TMC2100-LA TRINAMIC-TMC2100-LA_17 Datasheet
1Mb / 48P
   POWER DRIVER FOR STEPPER MOTORS
TMC2224-LA TRINAMIC-TMC2224-LA Datasheet
2Mb / 79P
   POWER DRIVER FOR STEPPER MOTORS
TMC2130_LA TRINAMIC-TMC2130_LA_17 Datasheet
2Mb / 103P
   POWER DRIVER FOR STEPPER MOTORS
TMC5072 TRINAMIC-TMC5072_17 Datasheet
2Mb / 107P
   POWER DRIVER FOR STEPPER MOTORS
TMC260-PA TRINAMIC-TMC260-PA Datasheet
1Mb / 53P
   POWER DRIVER FOR STEPPER MOTORS
TMC260 TRINAMIC-TMC260 Datasheet
1Mb / 53P
   POWER DRIVER FOR STEPPER MOTORS
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.NET
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com