background image
3.6~4.4V
VOLTAGE ADJ. RANGE
110~140% rated output power
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
2000ms, 80ms/230VAC
3000ms, 80ms/115VAC at full load
90 ~ 264VAC
127 ~ 370VDC
Cold start 30A/115VAC
60A/230VAC
<0.75mA / 240VAC
-30 ~ +70
(Refer to “
")
Derating Curve
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH non-condensing
±℃
℃)
0.03%/
(0 ~ 50
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
285 K hrs min.
MIL-HDBK-217F (25
)
PF
0.94/230VAC PF
0.98/115VAC at full load
≥≥
10ms/230VAC
10ms/115VAC
89%
±1.0%
±0.5%
±2.0%
150mVp-p
4.2V
File Name:UHP-350-SPEC 2017-08-23
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance :
line regulation and load regulation.
includes set up tolerance,
4. Derating may be needed under low input voltages. Please check the
for more details.
derating curve
5.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft)
℃℃
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.
meanwell.com)
ENVIRONMENT
PROTECTION
94%
220*62*31mm (L*W*H)
Protection type :Shut down O/P voltage,re-power on to recover
Protection type :Shut down O/P voltage, recovers automatically after
temperature goes down
4A/115VAC
2A/230VAC
RATED POWER(convection)
0.68 kg;16 pcs/11.88 kg/0.63CUFT
47 ~ 63Hz
Protection type : Hiccup mode, recovers automatically after fault condition is removed
91%
4.5~5.5V
±1.0%
±0.5%
±2.0%
200mVp-p
5V
11.4~12.6V
±0.5%
±0.3%
±1.0%
200mVp-p
12V
14.3~15.8V
200mVp-p
15V
22.8~25.2V
240mVp-p
24V
34.2~37.8V
240mVp-p
36V
45.6~50.4V
240mVp-p
48V
±0.5%
±0.3%
±1.0%
±0.5%
±0.3%
±1.0%
±0.5%
±0.3%
±1.0%
±0.5%
±0.3%
±1.0%
90%
92%
94%
94%
UHP-350 series
FUNCTION
DC OK SIGNAL(Optional)
REDUNDANT(Optional)
Contact rating(max.):15Vdc/10mA resistive load
For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically
enabled. This can prevent the system crash, and provide the reliability of system
350W Slim Type with PFC Switching Power Supply
SAFETY STANDARDS
EMC EMISSION
EMC IMMUNITY
Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3
SAFETY &
EMC
(Note.6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:1.25KVAC
I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25
/ 70%RH
Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A
UL60950-1,TUV EN60950-1,
CCC GB4943 approved
EN60335-1,
60A
252W
60A
300W
29.2A
350.4W
23.4A
351W
14.6A
350.4W
9.75A
351W
7.3A
350.4W
4.62 ~ 5.46V
39.6 ~46.8V
13.2 ~ 15.6V
5.75 ~ 6.75V
16.5 ~ 19.5V
26.4 ~ 31.2V
52.8 ~ 62.4V
88.5%
3.8 ~ 4.6V
3.2~3.5V
±0.5%
±2.0%
150mVp-p
3.3V
UHP-350
-4.2 UHP-350
-5 UHP-350
-12
UHP-350
-15
UHP-350
-24 UHP-350
-36 UHP-350
-48
UHP-350
-3.3
60A
198W
±1.0%




Html Pages

1  2  3  4  5  6 


Datasheet Download




Link URL

Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Bookmark   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com 2003 - 2017    


Mirror Sites
English : Alldatasheet.com  , Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp  |   Russian : Alldatasheetru.com
Korean : Alldatasheet.co.kr   |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com  |   Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl