Electronic Components Datasheet Search |
|
LMS3655MMRNLR Datasheet(PDF) 5 Page - Texas Instruments |
|
|
LMS3655MMRNLR Datasheet(HTML) 5 Page - Texas Instruments |
5 / 52 page 5 LMS3655 www.ti.com SNAS744A – JULY 2017 – REVISED OCTOBER 2017 Product Folder Links: LMS3655 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated (1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions are not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. (2) A maximum of 42 V can be sustained at this pin for a duration of ≤ 500 ms at a duty cycle of ≤ 0.01%. (3) A voltage of 2 V below PGND and 2 V above VIN can appear on this pin for ≤ 200 ns with a duty cycle of ≤ 0.01%. (4) Do not exceed the voltage rating on this pin. 7 Specifications 7.1 Absolute Maximum Ratings Over the recommended operating junction temperature range of –40°C to +150°C (unless otherwise noted). (1) PARAMETER MIN MAX UNIT VIN (AVIN, PVIN1, and PVIN2) to AGND, PGND(2) –0.3 40 V SW to AGND, PGND(3) –0.3 VIN + 0.3 V CBOOT to SW –0.3 3.6 V EN to AGND, PGND(2) –0.3 40 V BIAS to AGND, PGND –0.3 16 V FB to AGND, PGND –0.3 16 V RESET to AGND, PGND –0.3 8 V RESET sink current(4) 10 mA SYNC to AGND, PGND(2) –0.3 40 V FPWM to AGND, PGND(2) –0.3 40 V VCC to AGND, PGND –0.3 3.6 V Junction temperature –40 150 °C Storage temperature, Tstg –40 150 °C (1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. (2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. 7.2 ESD Ratings VALUE UNIT V(ESD) Electrostatic discharge Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) ±1000 V Charged-device model (CDM), per JEDEC specification JESD22-C101(2) ±250 (1) An extended input voltage range to 3.5 V is possible; see System Characteristics table. See Input UVLO for start-up conditions. (2) The output voltage must not be allowed to fall below zero volts during normal operation. (3) Operation below 3.3 V and above 6 V may require changes to the typical application schematic, operation may not be possible over the full input voltage range, and some system specifications will not be achieved for this extended output voltage range. Consult the factory for further information. (4) High junction temperatures degrade operating lifetime. 7.3 Recommended Operating Conditions Over the recommended operating junction temperature range of –40°C to +150°C (unless otherwise noted). MIN NOM MAX UNIT Input voltage after start-up(1) 3.9 36 V Output adjustment for LMS3655(2) 3.3 6 V Extended output adjustment for LMS3655(3) 1 15 V Load current for LMS3655 5.5 A Operating ambient temperature(4) –40 125 °C |
Similar Part No. - LMS3655MMRNLR |
|
Similar Description - LMS3655MMRNLR |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |